Pryde Measurement Pty Ltd - Biotector (formally PCS - Pollution Control Systems)
RETURN TO HOME





BioTector System-C

BioTector System-C Online TOC Analyzer was developed to meet the needs of a specific market segment - Clean Water Applications.

Some features of the existing BioTector series are not required in these applications eg. particulate handling and the ability to manage Fats, Oils and Greases. But customers with clean water applications still want the reassuring quality of a BioTector Analyzer. So, in response to their feedback, we developed the System-C Online TOC Analyzer.

BioTector System-C for clean water applications will give you process insights, process incident alerts, environmental monitoring, energy optimisation, product loss prevention, water loss prevention, boiler protection and plant protection.

And it comes with the award-winning performance that you expect from the BioTector patented Two-Stage Advanced Oxidation technology (TSAO).

Features:

  • Lightweight and portable analyzer
  • Dimensions: 750 x 500 x 320 mm
  • Low cost option for low range clean TOC analysis
  • Certified accuracy better than +/- 3% of reading or +/- 0.03mgC/l (30ppb), whichever is greater
  • Certified uptime of 99.86%
  • Minimal maintenance – needs only two routine maintenance events per year
  • Captures and quantifies volatile components in TOC measurement while excluding and quantifying inorganic carbon content of the stream
  • Continuous online analysis with the ability to instantly stop and start when required
  • Hazardous and non-hazardous area options
  • Low cost of ownership
  • Lowest reagent consumption for TOC measurement
  • Rapid payback on investment

Biotector System-C Data Sheet








TOC Online Analyser

General Information

Designed to withstand corrosive environments, the BioTector TOC Analyzer is housed in an FRP enclosure with dual compartments to keep all electronic components separate from the “wet” or analysis section. The BioTector TOC Analyzer has an in-built microcontroller and is operated through a membrane keypad. An SD Falsh Card allows easy software & configuration updates and may be used to download the 5,000 event archive.

Features & Benefits

  • Low Maintenance - No calibration required between 6 month service intervals
  • High Reliability - Typically 99.7% Uptime
  • Self Cleaning Technology - Prevents clogging & sample contamination
  • Clean & Dirty water analysis (including fats, oils & greases)
  • Can handle chlorides up to 30% and calcium sludge up to 12% by volume
  • No filtering requirements
  • Complete Oxidation of Representative Sample using Patented Two-Stage Advanced Oxidation (TSAO) Technology
  • Multi Range with automatic selection
  • Single or Multi-Stream Option
  • Measured Components: TOC, COD, BOD, TC, TIC, VOC
  • Very low cost of ownership
  • Guaranteed to handle the most demanding applications

TOC Online Analyser Data Sheet










TOC-TN Total Nitrogen Online Analyser

The TN, or Total Nitrogen, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds (for TOC measurement) it also oxidizes bound (organic and inorganic) nitrogen compounds and ammonium compounds into nitrate (NO3-). This nitrate is present as an aqueous ion in the oxidized sample fluid in the BioTector reactor.

When TOC analysis is complete, the sample fluid is brought from the reactor into a measuring cell. Here the spectrophotometer analyzes the wavelengths applicable to nitrates. The result is displayed as Total Nitrogen (TN). A cleaning fluid is then passed through the measuring cell automatically, which ensures that operator cleaning and maintenance is kept to an absolute minimum.

Features & Benefits

  • Low Maintenance - No calibration required between 6 month service intervals
  • High Reliability - Typically 99.7% Uptime
  • Self Cleaning Technology - Prevents clogging & sample contamination
  • Clean & Dirty water analysis (including fats, oils & greases)
  • Can handle chlorides up to 30% and calcium sludge up to 12% by volume
  • No filtering requirements
  • Complete Oxidation of Representative Sample using Patented Two-Stage Advanced Oxidation (TSAO) Technology
  • Multi Range with automatic selection
  • Single or Multi-Stream Option
  • Measured Components: TOC, TN, COD, BOD, TC, TIC, VOC
  • Very Low Cost of Ownership
  • Guaranteed to handle the most demanding applications

TOC-TN Total Nitrogen Online Analyser Data Sheet





TOC-TP Total Phosphorus Online Analyser

The TP, or Total Phosphorous, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds for TOC measurement, it also reduces phosphorus compounds (with the exception of poly-phosphates) to orthophosphates (PO4-). This phosphate is present as an ion in the oxidized sample fluid in the BioTector reactor

OOP Measurement
When both TOC and TN analysis are complete, the sample fluid is reacted with a Vanadate-Molybdate reagent at 70°C to produce an acidic compound. The spectrophotometer then analyzes this sample at the wavelengths applicable to ortho-phosphates. The result is displayed as Oxidized and Ortho-Phosphorus (OOP). For applications without any polyphosphates, the OOP is equal to TP.

TP Measurement
For applications with significant polyphosphate concentrations a further step is required to arrive at the TP result. The sample fluid undergoes an acid boiling at 100°C for 20 minutes, breaking down the polyphosphate bonds into ortho-phosphates. The result is displayed as Total Phosphorus (TP), which is measured using the procedure described above for OOP Analysis.

Features & Benefits

  • Low Maintenance - No Calibration required between 6 month service intervals
  • High Reliability - Typically 99.7% Uptime
  • Self Cleaning Technology - Prevents clogging & sample contamination
  • Clean & Dirty water analysis (including fats, oils & greases)
  • Can handle chlorides up to 30% and calcium sludge up to 12% by volume
  • No filtering requirements
  • Complete Oxidation of Representative Sample using Patented Two-Stage Advanced Oxidation (TSAO) Technology
  • Multi Range with automatic selection
  • Single or Multi-Stream Option
  • Measured Components: TOC, TN, OOP, TP, COD, BOD, TC, TIC, VOC
  • Very Low Cost of Ownership
  • Guaranteed to handle the most demanding applications

TOC-TP Total Phosphorus Online Analyser Data Sheet





BIOTECTOR VACUUM SAMPLER Water sampling system for analyzers.

Product overview

  • Sample container: PVC
  • Sample volume: 400ml
  • Pinch valve with EMPP tube
  • Main sample line 3/8” OD x 1/4” ID
  • Automatic fault indication

General Information

The BioTector vacuum sampling system is designed to bring water over a distance of 40 meters with a maximum lift of 6 meters, and to present the sample to the BioTector TOC analyzer, or alternative water analyzer, at ambient pressure.

Functions

  • The vacuum sampler pump generates a vacuum in the sample container which draws the sample up into the sample container.
  • A built-in conductivity probe confirms that the sample has filled the container. The vacuum pump is stopped, a pinch valve closes to seal the sample in the container and vacuum valves open to restore the pressure in the sample container to ambient. If the sample does not make contact with the conductivity probe within a pre-set time, a fault condition is triggered.
  • The analyzer takes a sample from the container. If necessary, a short sedimentation period (to allow sand and hard particles to settle) may be programmed before the analyzer takes its sample.
  • When the sample has been taken, the pinch valve opens. The vacuum pump, through a series of valves, generates pressure in the sample container, which forces the sample from the container back through the sample line.
  • The cycle then repeats.

Biotector Vacuum Sampler Data Sheet





Pryde Measurement Pty. Ltd.,
ACN 112 029 777
National Customer Service - Free Call: 1800-688-211

 

Brisbane
Carole Park, QLD 4300
Phone: (03) 9567 0777
Melbourne
750 Queensberry Street,
North Melbourne, VIC 3051
Phone: (03) 9567 0777

Perth
Kwinana, WA 6966
Phone: 0427 517 359
P.O. Box 193
Kwinana, WA 6966

Sydney
Suite 2C, Centennial House
10 Ingleburn Road.
Ingleburn, NSW 2565
Phone: (02) 9618 5822
P.O.Box 327,
Ingleburn, NSW 2565