JES-301 Gas Sampling Probe
Applications:
- For continous gas sampling in processes with dust content and humidity
- Removing aerosols and dust from sample
- Extractive gas analysis
- Emission monitoring and process monitoring
- For outdoor and indoor use
Benefits:
- Convenient filter replacement
- Rapid availability
- Low maintenance Operation
Features:
- Filter replacement without tools
- Filtration from outside to inside
- Calibration gas port (option)
- Backpurge port (option)
- Heated sample hose is connected directly to heated sampling probe
- Weather protection housing
- For high dust concentrations
- Temperature status contact
- Temperature controller
- Wide range of accessories
JES-301 Data Sheet
|
|
|
|
JES-301G Gas Sampling Probe steam heated
Applications:
- For continous gas sampling in processes with dust content and humidity
- Removing aerosols and dust from sample
- Extractive gas analysis
- Emission monitoring and process monitoring
- For outdoor and indoor use, also in ATEX zone 1 and 2
Benefits:
- Convenient filter replacement
- No electric parts
- Low maintenance Operation
Features:
- Filter replacement without tools
- Filtration from outside to inside
- Steam heated
- Temperature control via steam pressure
- Calibration gas port (option)
- Backpurge port (option)
Heated sample hose is connected directly to steam heated sampling probe
- For high dust concentrations
- Made of stainless steel
- Wide range of accessories
JES-301G Data Sheet
|
|
|
|
JES-301K Back Purge Control Unit
Applications:
- For extractive gas analysis
- For emission and process monitoring
- For control of automatic back purge of JCT gas sampling probes series JES-301
- For applications with high dust concentrations
- For regular cleaning of probe filter, filter chamber and possible pre-filter
Benefits:
- For in and outdoor mounting suitable
- Fully programmed two stage back purge program
- Easy adjustment of the back purge cycles by connection of only one cable
- Save operation due to status message
- No entry of purge gas into sample gas possible
Features:
- In robust weatherproof FRP housing
- For wall mounting
- PLC (programmable logic controller)
- Adjustable interval for back purge cycles
- Status contact
- Safety shut off valve
- Control for process shut off valve
JES-301K Data Sheet
|
|
|
|
JER Sampling Pipes and JHD Pre-Filters
Applications:
- For extractive gas analysis
- For emission and process monitoring
- For gas sampling at corrosive process gases
- For gas sampling at process temperatures up to 1800°C
- For gas sampling at high dust concentrations > 2g/m3
- For adaption to all stationary JCT gas sampling probes
Benefits:
- Easy mounting
- Optimal adaption of JCT gas sampling probes to the widest range of sampling conditions due to a huge variety of products
- Precisely definable gas sampling point due to huge variaty of sampling and extension pipes
- Pre-filter with V-deflector applicable also at high flow velocities in the process without damage
- Simple exchange
Features:
- Wide range of different sampling pipe and pre-filter materials
- Wide range of different sampling pipe and pre-filter lengths
- All sampling pipes and pre-filters with G3/4male thread
- Wide range of different extension tubes for pre-filter placement in the process
- Pre-filter also with V-deflector for protection against abrasion
- All sampling pipes and pre-filters with mounting hexagon
|
|
|
|
JER-EH Heated Sampling Pipe
Applications:
- For extractive gas analysis
- For emission and process monitoring
- For avoidance of acid dew point lower deviaton between sampling point and gas sampling probe
- Combinable with gas sampling probes JES-301 and JES-301L
Benefits:
- Sampling without influence on the sample gas
- No corrosion due to condensate formation
- Homogeneous heating of interior and exterior pipe to 180°C due to even temperature distribution across the whole heat conductor length, independent of the operating conditions
- Easy mounting
- Pre-filter and extensions adaptable
- No temperature sensor necessary with HTI-16
- Pt100 temperature sensor with JTC-308
- Illuminated temperature display
Features:
- Corrosion resistant double shell pipe with internal heating
- Heating failure monitoring with alarm contact and indication
- Mounting directly at the standard process flange
- Tube length of 500 to 2000 mm available
- Controlled heating up to 180°C
- Electronic temperature controller with temperature display
- Controller for wall mounting or directly mounted at the sampling tube (option)
- Electrical connection with plug connection STAS200 for temperature controller HTI-16 or turn-key mounted with JTC-308
JER-EH Data Sheet
|
|
|
|
JES-301L Gas Sampling Probe
Applications:
- For continous gas sampling in processes with dust content and humidity
- Removing aerosols and dust from sample
- Extractive gas analysis
- Emission monitoring and process monitoring
- For outdoor and indoor use
Benefits:
- Convenient filter replacement
- Small outlines
- Quick heat up, max. 30 min.
- Suitable for standard applications
Features:
- Filter replacement without tools
- 2 µm filter element heated to 180°C
- Filtration from outside to inside
- Calibration gas port (option)
- Heated sample hose connected directly to heated sampling probe
- Weather protection housing
- For dust concentrations up to 1 g/m³
- Self regulating PTC heater
- Low temperature status contact
- No temperature controller needed
JES-301L Data Sheet
|
|
|
|
JES-301E1 Gas Sampling Probe
Applications:
- For continuous gas sampling in processes with dust and humidity
- Ex-version Zone 1 or 2
- Removing aerosols and dust from gas sample
- Extractive gas analysis
- Emission monitoring and process monitoring
- For outdoor and indoor use
Benefits:
- Convenient filter replacement
- Rapid availability
- Low maintenance Operation
Features:
- Filter replacement without tools
- Large filter surface
- Filtration from outside to inside
- Calibration gas port (option)
- Backpurge port (option)
- Heated sample hose is connected directly to heated sampling probe
- Weather protection housing
- For high dust concentrations
- Self-limited Ex-heater
- No temperature controller needed
- Wide range of accessories
JES-301E1 Data Sheet
|
|
|
|
JES-301E1SVZ Gas Sampling Probe
Applications:
- The gas sampling probe JES 301E1SVZ is for continuous use with extractive sampling systems even where the sample contains dust and aerosols in Zone 1.
- The JES 301E1SVZ is available in several versions which may be custom configured to meet user's specific requirements.
- The JES 301Ex incorporates a non-corrosive heated, replaceable ceramic filter element with a filter porosity of 2 micron.
- The filter element is mounted in an electrically heated stainless steel housing, which is installed in a thermally isolated weather protection housing.
- The temperature regulation is done by a maintenance free, PTC heater.
- A cut off valve allows shutting off the gas flow on the raw-gas side.
- The heated line series JH can be easily connected to the JES 301Ex by a movable PG42 fastening screw.
Benefits:
- The gas sampling probe JES 301E1SVZ is a complete unit, consisting of the heated filter head, mounting flange and probe assembly.
- It can be mounted anywhere horizontally or vertically.
- The probe can be connected with a standard 2” ANSI flange directly.
- The flange material is stainless steel.
- When mounted horizontally, the JES 301E1SVZ should be built in an angle at least between 5° and 15° from the horizontals falling, to allow condensate flow back into the process.
- A broad range of different materials for In-Situ probe tubes, and large In-Situ-pre filters make the JES 301E1SVZ versatile in application.
Features:
- EX version - zone 1
- Rugged construction
- Easy filter replacement
- Low maintenance
- Self limited Ex-heater
- Cut off valve on raw-gas side
JES-301E1SVZ Data Sheet
|
|
|
|
JES-301KE1 Back Purge Control Unit for Ex-Zone 1
Applications:
- For extractive gas analysis
- For emission and process monitoring in Ex-area zone 1
- For control of automatic back purge of explosion proof JCT gas sample probes series JES-301
- For applications with high dust concentrations
- For regular cleaning of probe filter, filter chamber and possible pre-filter
Benefits:
- For in and outdoor mounting suitable
- For direct connection to inert gas or pressure air network
- No entry of purge gas into sample gas possible
- Protection against unauthorised access
- Fully programmed two stage back purge program (option PLC)
- Save operation due to status message (option PLC)
- Easy adjustment of the back purge cycles by connection of only one cable (option PLC)
Features:
- In robust weatherproof stainless steel housing
- For wall mounting
- Lockable housing
- Integrated pressure regulator for inert gas or compressed air
- 2 explosion-proof solenoid valves (safety shut off valve and clocked back purge valvel)
- Manual shut off ball valve in the inlet
- External PLC (programmable logic controller) with adjustable interval for back purge cycles and status contact for mounting in explosion-free area as option
JES-301KE1 Data Sheet
|
|
|
|
JHPF Heated Adapter Pipe
Applications:
- For extractive gas analysis
- For emission and process monitoring
- Process external heating of pre-filters for applications with high dust concentrations combined with high process temperatures (above maximum temperature of pre-filter)
- Combinable with gas sampling probes JES-351, JES-352 und JES-353
Benefits:
- Sampling without influence on the sample gas
- No corrosion due to condensate formation
- Uniform reliable heating of the pre-filters independant of the operating conditions
- Cleaning via back purge connection
- Easy mounting
- Safe operation
Features:
- Corrosion resistant stainless steel pipe
- Fully electronic temperature controller with low temperature alarm and excess temperature switch-off
- Error message for sensor short-circuit and broken sensor
- Mounting directly at the standard process and gas sampling probe flange
- Pipe length 400 mm
- Temperature adjustment range 5°C....200°C
- Sampling pipes of arbitrary length can be screwed in on process side Back purge connection with check valve
JHPF Data Sheet
|
|
|
|
JCS-100 Sample Gas Compressor Cooler
Applications:
- For extractive gas analysis
- For emission and process monitoring
- Continuous drying of sample gas to a precise low and constant outlet dew point
- Minimises water vapour cross sensitivities and volumetric errors
Benefits:
- High flow rates and water vapour dew points possible
- Easy to change heat exchangers
- Continuous condensate removal
- Low maintenance operation
Features:
- Proven and reliable technology
- Various heat exchanger materials
- One or two independent gas paths
- Digital temperature indication
- Integrated condensate pump
- Status contact with acoustic feedback
- Hot gas bypass compressor technology
- Temperature sensor monitoring
- High current volt free status relay outputs (direct pump switching)
- Long life fan with ball bearing
- Wall mount, optional free stand
- Fully encapsulated temperature sensor
- Small footprint
- Stainless steel housing
- Light weight
JCS-100 Data Sheet
|
|
|
|
JCT-1 & JCT-2 Compact and Midi Sample Gas Compressor-Coolers
Applications:
- For extractive gas analysis
- For emission and process monitoring
- Continuous drying of sample gas to a precise low and constant outlet dew point
- inimises water vapour cross sensitivities and volumetric errors
Benefits:
- Extremlely precise long term stable dew point even under varying loads
- High flow rates and water vapour dew points possible
- Easy to change heat exchangers
- Continuous condensate removal
- Low maintenance operation
- Easy to maintain design
Features:
- Proven and reliable technology
- Performance optimised construction
- High performance heat exchanger
- Heat exchanger material PVDF, Duran glass or stainless steel
- One or two independant gas paths
- Proportional temperature controller
- Digital temperature indication
- Integrated condensate pump
- Status contact
- Compact design
JCT 1 & JCT-2 Data Sheet
|
|
|
|
JCT-3 Grand Sample Gas Compressor-Cooler
Applications:
- For extractive gas analysis
- For emission and process monitoring
- Continuous drying of sample gas to a precise low and constant outlet dew point
- Minimises water vapour cross sensitivities and volumetric errors
Benefits:
- Extremlely precise long term stable dew point even under varying loads
- High flow rates and water vapour dew points possible
- Easy to change heat exchangers
- Continuous condensate removal
- Low maintenance operation
- Easy to maintain design
Features:
- Proven and reliable technology
- Performance optimised construction
- High performance heat exchanger
- Heat exchanger material PVDF, Duran glass oder stainless steel
- One to four independant gas paths
- Proportional temperature controller
- Digital temperature indication
- Integrated condensate pump Status contact
JCT-3 Data Sheet
|
|
|
|
JCE-2 Ex Midi Sample Gas Compressor Cooler
Applications:
- For operation in Ex-zone 2
- For extractive gas analysis
- For emission and process monitoring
- Continuous drying of sample gas to a precise low and constant outlet dew point
- Minimises water vapour cross sensitivities and volumetric errors
Benefits:
- Extremlely precise long term stable dew point even under varying loads
- High flow rates and water vapour dew points possible
- Easy to change heat exchangers
- Continuous condensate removal
- Low maintenance operation
- Easy to maintain design
Features:
- Proven and reliable technology with ATEX approval
- Performance optimised construction
- High performance heat exchanger with flow rates up to 350 Nl/hr
- Heat exchanger material PVDF or stainless steel
- One or two independant gas paths
- Proportional temperature controller
- Digital temperature display
- Integrated condensate pumps
- Status contact
- Compact design
JCE-2 Data Sheet
|
|
|
|
JCL-301 Compact Gas Conditioning System
Applications:
- For extractive gas analysis
- For emission and process monitoring
- Continuous sample gas conditioning of humid process gases
- Continuous drying of sample gas to a precise low and constant outlet dew point
- Minimises water vapour cross sensitivities and volumetric errors
Benefits:
- Complete solution for a great number of applications
- Longterm reliable reproducable measuring results
- Optimum operational safety due to self-monitoring
- Extremlely precise long term stable dew point even under varying loads
- Fast response time due to low dead volume
- Very low dissolution rates
- Continuous condensate removal
- Low maintenance operation
- Easy to maintain design
Features:
- Individual configuration due to various expansion options
- Basic device with high-performance compressor sample gas cooler
- 1 or 2 independant sample gas paths
- Integrated condensate pumps
- Speed-controlled fan
- Connections for external sample gas pump
- 11 status-LEDs with event memory
- 2 status contacts
- Additional options:
- Easy to maintain robust fine dust filter
- Corrosion resistant flowmeter with precise needle valve
- Reliable condensate monitoring
- Acid dosing pump
- RS 485 interface
JCL-301 Data Sheet
|
|
|
|
JCL-304 / JCL-319 Gas Conditioning Systems
Applications:
- For extractive gas analysis
- For emission and process monitoring
- Continuous sample gas conditioning of humid process gases
- Continuous drying of sample gas to a precise low and constant outlet dew point
- Minimises water vapour cross sensitivities and volumetric errors
Benefits:
- Complete solution for a great number of applications
- Longterm reliable reproducable measuring results
- Optimum operational safety due to self-monitoring
- Extremlely precise long term stable dew point even under varying loads
- Fast response time due to low dead volume
- Very low dissolution rates
- Continuous condensate removal
- Low maintenance operation
- Easy to maintain design
Features:
- For wall or 19"-rack mounting
- Individual configuration due to modular design
- Basic device with high-performance compressor sample gas cooler
- 1 to 4 independant sample gas paths
- Integrated condensate pumps
- Speed controlled fan
- 11 status-LEDs with event memory
- 2 status contacts
- Additional options:
- High performance corrosion resistant sample gas pump
- Easy to maintain robust fine dust filter
- Corrosion resistant flowmeter with precise needle valve
- Reliable condensate monitoring
- Acid dosing pump
- RS 485 interface
JCL-304 / JCL-319 Data Sheet
|
|
|
|
JCC-R / JCC-Q / JCC-P / JCC-L Gas Conditioning Systems
Applications:
- For mobile or stationary extractive gas analysis
- For emission and process monitoring
- Continuous sample gas conditioning of humid process gases
- Continuous drying of sample gas to a precise low and constant outlet dew point
- Minimises water vapour cross sensitivities and volumetric errors
Benefits:
- Complete solution for a great number of applications
- Sustainable reproducable measuring results
- Optimum operational safety due to self-monitoring
- Extremlely precise long term stable dew point even under varying loads
- Fast response time due to low dead volume
- Continuous condensate removal
- Low maintenance operation
- Easy to maintain design
Features:
- 4 housing versions:
- 19" mounting
- Rear panel mounting
- Side panel mounting
- Portable housing
- Individual configuration due to modular design
- Basic device with high-performance compressor sample gas cooler
- Integrated condensate pumps
- Digital temperature display and status-LEDs
- Status contact
- Additional options:
- High performance corrosion resistant sample gas pump with safety interlock
- Easy to maintain robust fine dust filter or disposable filter
- Corrosion resistant flowmeter with precise needle valve
- Reliable condensate monitoring
JCC-R / JCC-Q / JCC-P / JCC-L Data Sheet
|
|