JES-301 Gas Sampling Probe

Applications:

  • For continous gas sampling in processes with dust content and humidity
  • Removing aerosols and dust from sample
  • Extractive gas analysis
  • Emission monitoring and process monitoring
  • For outdoor and indoor use

Benefits:

  • Convenient filter replacement
  • Rapid availability
  • Low maintenance Operation

Features:

  • Filter replacement without tools
  • Filtration from outside to inside
  • Calibration gas port (option)
  • Backpurge port (option)
  • Heated sample hose is connected directly to heated sampling probe
  • Weather protection housing
  • For high dust concentrations
  • Temperature status contact
  • Temperature controller
  • Wide range of accessories

JES-301 Data Sheet







JES-301G Gas Sampling Probe steam heated

Applications:

  • For continous gas sampling in processes with dust content and humidity
  • Removing aerosols and dust from sample
  • Extractive gas analysis
  • Emission monitoring and process monitoring
  • For outdoor and indoor use, also in ATEX zone 1 and 2

Benefits:

  • Convenient filter replacement
  • No electric parts
  • Low maintenance Operation

Features:

  • Filter replacement without tools
  • Filtration from outside to inside
  • Steam heated
  • Temperature control via steam pressure
  • Calibration gas port (option)
  • Backpurge port (option)
    Heated sample hose is connected directly to steam heated sampling probe
  • For high dust concentrations
  • Made of stainless steel
  • Wide range of accessories

JES-301G Data Sheet







JES-301K Back Purge Control Unit

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • For control of automatic back purge of JCT gas sampling probes series JES-301
  • For applications with high dust concentrations
  • For regular cleaning of probe filter, filter chamber and possible pre-filter

Benefits:

  • For in and outdoor mounting suitable
  • Fully programmed two stage back purge program
  • Easy adjustment of the back purge cycles by connection of only one cable
  • Save operation due to status message
  • No entry of purge gas into sample gas possible

Features:

  • In robust weatherproof FRP housing
  • For wall mounting
  • PLC (programmable logic controller)
  • Adjustable interval for back purge cycles
  • Status contact
  • Safety shut off valve
  • Control for process shut off valve

JES-301K Data Sheet







JER Sampling Pipes and JHD Pre-Filters

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • For gas sampling at corrosive process gases
  • For gas sampling at process temperatures up to 1800°C
  • For gas sampling at high dust concentrations > 2g/m3
  • For adaption to all stationary JCT gas sampling probes

Benefits:

  • Easy mounting
  • Optimal adaption of JCT gas sampling probes to the widest range of sampling conditions due to a huge variety of products
  • Precisely definable gas sampling point due to huge variaty of sampling and extension pipes
  • Pre-filter with V-deflector applicable also at high flow velocities in the process without damage
  • Simple exchange

Features:

  • Wide range of different sampling pipe and pre-filter materials
  • Wide range of different sampling pipe and pre-filter lengths
  • All sampling pipes and pre-filters with G3/4“male thread
  • Wide range of different extension tubes for pre-filter placement in the process
  • Pre-filter also with V-deflector for protection against abrasion
  • All sampling pipes and pre-filters with mounting hexagon









JER-EH Heated Sampling Pipe

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • For avoidance of acid dew point lower deviaton between sampling point and gas sampling probe
  • Combinable with gas sampling probes JES-301 and JES-301L

Benefits:

  • Sampling without influence on the sample gas
  • No corrosion due to condensate formation
  • Homogeneous heating of interior and exterior pipe to 180°C due to even temperature distribution across the whole heat conductor length, independent of the operating conditions
  • Easy mounting
  • Pre-filter and extensions adaptable
  • No temperature sensor necessary with HTI-16
  • Pt100 temperature sensor with JTC-308
  • Illuminated temperature display

Features:

  • Corrosion resistant double shell pipe with internal heating
  • Heating failure monitoring with alarm contact and indication
  • Mounting directly at the standard process flange
  • Tube length of 500 to 2000 mm available
  • Controlled heating up to 180°C
  • Electronic temperature controller with temperature display
  • Controller for wall mounting or directly mounted at the sampling tube (option)
  • Electrical connection with plug connection STAS200 for temperature controller HTI-16 or turn-key mounted with JTC-308

JER-EH Data Sheet







JES-301L Gas Sampling Probe

Applications:

  • For continous gas sampling in processes with dust content and humidity
  • Removing aerosols and dust from sample
  • Extractive gas analysis
  • Emission monitoring and process monitoring
  • For outdoor and indoor use

Benefits:

  • Convenient filter replacement
  • Small outlines
  • Quick heat up, max. 30 min.
  • Suitable for standard applications

Features:

  • Filter replacement without tools
  • 2 µm filter element heated to 180°C
  • Filtration from outside to inside
  • Calibration gas port (option)
  • Heated sample hose connected directly to heated sampling probe
  • Weather protection housing
  • For dust concentrations up to 1 g/m³
  • Self regulating PTC heater
  • Low temperature status contact
  • No temperature controller needed

JES-301L Data Sheet







JES-301E1 Gas Sampling Probe

Applications:

  • For continuous gas sampling in processes with dust and humidity
  • Ex-version Zone 1 or 2
  • Removing aerosols and dust from gas sample
  • Extractive gas analysis
  • Emission monitoring and process monitoring
  • For outdoor and indoor use

Benefits:

  • Convenient filter replacement
  • Rapid availability
  • Low maintenance Operation

Features:

  • Filter replacement without tools
  • Large filter surface
  • Filtration from outside to inside
  • Calibration gas port (option)
  • Backpurge port (option)
  • Heated sample hose is connected directly to heated sampling probe
  • Weather protection housing
  • For high dust concentrations
  • Self-limited Ex-heater
  • No temperature controller needed
  • Wide range of accessories

JES-301E1 Data Sheet







JES-301E1SVZ Gas Sampling Probe

Applications:

  • The gas sampling probe JES 301E1SVZ is for continuous use with extractive sampling systems even where the sample contains dust and aerosols in Zone 1.
  • The JES 301E1SVZ is available in several versions which may be custom configured to meet user's specific requirements.
  • The JES 301Ex incorporates a non-corrosive heated, replaceable ceramic filter element with a filter porosity of 2 micron.
  • The filter element is mounted in an electrically heated stainless steel housing, which is installed in a thermally isolated weather protection housing.
  • The temperature regulation is done by a maintenance free, PTC heater.
  • A cut off valve allows shutting off the gas flow on the raw-gas side.
  • The heated line series JH can be easily connected to the JES 301Ex by a movable PG42 fastening screw.

Benefits:

  • The gas sampling probe JES 301E1SVZ is a complete unit, consisting of the heated filter head, mounting flange and probe assembly.
  • It can be mounted anywhere horizontally or vertically.
  • The probe can be connected with a standard 2” ANSI flange directly.
  • The flange material is stainless steel.
  • When mounted horizontally, the JES 301E1SVZ should be built in an angle at least between 5° and 15° from the horizontals falling, to allow condensate flow back into the process.
  • A broad range of different materials for In-Situ probe tubes, and large In-Situ-pre filters make the JES 301E1SVZ versatile in application.

Features:

  • EX version - zone 1
  • Rugged construction
  • Easy filter replacement
  • Low maintenance
  • Self limited Ex-heater
  • Cut off valve on raw-gas side

JES-301E1SVZ Data Sheet







JES-301KE1 Back Purge Control Unit for Ex-Zone 1

Applications:

  • For extractive gas analysis
  • For emission and process monitoring in Ex-area zone 1
  • For control of automatic back purge of explosion proof JCT gas sample probes series JES-301
  • For applications with high dust concentrations
  • For regular cleaning of probe filter, filter chamber and possible pre-filter

Benefits:

  • For in and outdoor mounting suitable
  • For direct connection to inert gas or pressure air network
  • No entry of purge gas into sample gas possible
  • Protection against unauthorised access
  • Fully programmed two stage back purge program (option PLC)
  • Save operation due to status message (option PLC)
  • Easy adjustment of the back purge cycles by connection of only one cable (option PLC)

Features:

  • In robust weatherproof stainless steel housing
  • For wall mounting
  • Lockable housing
  • Integrated pressure regulator for inert gas or compressed air
  • 2 explosion-proof solenoid valves (safety shut off valve and clocked back purge valvel)
  • Manual shut off ball valve in the inlet
  • External PLC (programmable logic controller) with adjustable interval for back purge cycles and status contact for mounting in explosion-free area as option

JES-301KE1 Data Sheet







JHPF Heated Adapter Pipe

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • Process external heating of pre-filters for applications with high dust concentrations combined with high process temperatures (above maximum temperature of pre-filter)
  • Combinable with gas sampling probes JES-351, JES-352 und JES-353

Benefits:

  • Sampling without influence on the sample gas
  • No corrosion due to condensate formation
  • Uniform reliable heating of the pre-filters independant of the operating conditions
  • Cleaning via back purge connection
  • Easy mounting
  • Safe operation

Features:

  • Corrosion resistant stainless steel pipe
  • Fully electronic temperature controller with low temperature alarm and excess temperature switch-off
  • Error message for sensor short-circuit and broken sensor
  • Mounting directly at the standard process and gas sampling probe flange
  • Pipe length 400 mm
  • Temperature adjustment range 5°C....200°C
  • Sampling pipes of arbitrary length can be screwed in on process side Back purge connection with check valve

JHPF Data Sheet







JCS-100 Sample Gas Compressor Cooler

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • Continuous drying of sample gas to a precise low and constant outlet dew point
  • Minimises water vapour cross sensitivities and volumetric errors

Benefits:

  • High flow rates and water vapour dew points possible
  • Easy to change heat exchangers
  • Continuous condensate removal
  • Low maintenance operation

Features:

  • Proven and reliable technology
  • Various heat exchanger materials
  • One or two independent gas paths
  • Digital temperature indication
  • Integrated condensate pump
  • Status contact with acoustic feedback
  • Hot gas bypass compressor technology
  • Temperature sensor monitoring
  • High current volt free status relay outputs (direct pump switching)
  • Long life fan with ball bearing
  • Wall mount, optional free stand
  • Fully encapsulated temperature sensor
  • Small footprint
  • Stainless steel housing
  • Light weight

JCS-100 Data Sheet







JCT-1 & JCT-2 Compact and Midi Sample Gas Compressor-Coolers

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • Continuous drying of sample gas to a precise low and constant outlet dew point
  • inimises water vapour cross sensitivities and volumetric errors

Benefits:

  • Extremlely precise long term stable dew point even under varying loads
  • High flow rates and water vapour dew points possible
  • Easy to change heat exchangers
  • Continuous condensate removal
  • Low maintenance operation
  • Easy to maintain design

Features:

  • Proven and reliable technology
  • Performance optimised construction
  • High performance heat exchanger
  • Heat exchanger material PVDF, Duran glass or stainless steel
  • One or two independant gas paths
  • Proportional temperature controller
  • Digital temperature indication
  • Integrated condensate pump
  • Status contact
  • Compact design

JCT 1 & JCT-2 Data Sheet







JCT-3 Grand Sample Gas Compressor-Cooler

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • Continuous drying of sample gas to a precise low and constant outlet dew point
  • Minimises water vapour cross sensitivities and volumetric errors

Benefits:

  • Extremlely precise long term stable dew point even under varying loads
  • High flow rates and water vapour dew points possible
  • Easy to change heat exchangers
  • Continuous condensate removal
  • Low maintenance operation
  • Easy to maintain design

Features:

  • Proven and reliable technology
  • Performance optimised construction
  • High performance heat exchanger
  • Heat exchanger material PVDF, Duran glass oder stainless steel
  • One to four independant gas paths
  • Proportional temperature controller
  • Digital temperature indication
  • Integrated condensate pump Status contact

JCT-3 Data Sheet







JCE-2 Ex Midi Sample Gas Compressor Cooler

Applications:

  • For operation in Ex-zone 2
  • For extractive gas analysis
  • For emission and process monitoring
  • Continuous drying of sample gas to a precise low and constant outlet dew point
  • Minimises water vapour cross sensitivities and volumetric errors

Benefits:

  • Extremlely precise long term stable dew point even under varying loads
  • High flow rates and water vapour dew points possible
  • Easy to change heat exchangers
  • Continuous condensate removal
  • Low maintenance operation
  • Easy to maintain design

Features:

  • Proven and reliable technology with ATEX approval
  • Performance optimised construction
  • High performance heat exchanger with flow rates up to 350 Nl/hr
  • Heat exchanger material PVDF or stainless steel
  • One or two independant gas paths
  • Proportional temperature controller
  • Digital temperature display
  • Integrated condensate pumps
  • Status contact
  • Compact design

JCE-2 Data Sheet







JCL-301 Compact Gas Conditioning System

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • Continuous sample gas conditioning of humid process gases
  • Continuous drying of sample gas to a precise low and constant outlet dew point
  • Minimises water vapour cross sensitivities and volumetric errors

Benefits:

  • Complete solution for a great number of applications
  • Longterm reliable reproducable measuring results
  • Optimum operational safety due to self-monitoring
  • Extremlely precise long term stable dew point even under varying loads
  • Fast response time due to low dead volume
  • Very low dissolution rates
  • Continuous condensate removal
  • Low maintenance operation
  • Easy to maintain design

Features:

  • Individual configuration due to various expansion options
  • Basic device with high-performance compressor sample gas cooler
  • 1 or 2 independant sample gas paths
  • Integrated condensate pumps
  • Speed-controlled fan
  • Connections for external sample gas pump
  • 11 status-LED’s with event memory
  • 2 status contacts
  • Additional options:
    • Easy to maintain robust fine dust filter
    • Corrosion resistant flowmeter with precise needle valve
    • Reliable condensate monitoring
    • Acid dosing pump
    • RS 485 interface

JCL-301 Data Sheet







JCL-304 / JCL-319 Gas Conditioning Systems

Applications:

  • For extractive gas analysis
  • For emission and process monitoring
  • Continuous sample gas conditioning of humid process gases
  • Continuous drying of sample gas to a precise low and constant outlet dew point
  • Minimises water vapour cross sensitivities and volumetric errors

Benefits:

  • Complete solution for a great number of applications
  • Longterm reliable reproducable measuring results
  • Optimum operational safety due to self-monitoring
  • Extremlely precise long term stable dew point even under varying loads
  • Fast response time due to low dead volume
  • Very low dissolution rates
  • Continuous condensate removal
  • Low maintenance operation
  • Easy to maintain design

Features:

  • For wall or 19"-rack mounting
  • Individual configuration due to modular design
  • Basic device with high-performance compressor sample gas cooler
  • 1 to 4 independant sample gas paths
  • Integrated condensate pumps
  • Speed controlled fan
  • 11 status-LED’s with event memory
  • 2 status contacts
  • Additional options:
    • High performance corrosion resistant sample gas pump
    • Easy to maintain robust fine dust filter
    • Corrosion resistant flowmeter with precise needle valve
    • Reliable condensate monitoring
    • Acid dosing pump
    • RS 485 interface

JCL-304 / JCL-319 Data Sheet






JCC-R / JCC-Q / JCC-P / JCC-L Gas Conditioning Systems

Applications:

  • For mobile or stationary extractive gas analysis
  • For emission and process monitoring
  • Continuous sample gas conditioning of humid process gases
  • Continuous drying of sample gas to a precise low and constant outlet dew point
  • Minimises water vapour cross sensitivities and volumetric errors

Benefits:

  • Complete solution for a great number of applications
  • Sustainable reproducable measuring results
  • Optimum operational safety due to self-monitoring
  • Extremlely precise long term stable dew point even under varying loads
  • Fast response time due to low dead volume
  • Continuous condensate removal
  • Low maintenance operation
  • Easy to maintain design

Features:

  • 4 housing versions:
    • 19“" mounting
    • Rear panel mounting
    • Side panel mounting
    • Portable housing
  • Individual configuration due to modular design
  • Basic device with high-performance compressor sample gas cooler
  • Integrated condensate pumps
  • Digital temperature display and status-LED’s
  • Status contact
  • Additional options:
    • High performance corrosion resistant sample gas pump with safety interlock
    • Easy to maintain robust fine dust filter or disposable filter
    • Corrosion resistant flowmeter with precise needle valve
    • Reliable condensate monitoring

JCC-R / JCC-Q / JCC-P / JCC-L Data Sheet




Pryde Measurement Pty. Ltd.,
ACN 112 029 777
National Customer Service - Free Call: 1800-688-211

 

Brisbane
Carole Park, QLD 4300
Phone: (03) 9567 0777
Melbourne
750 Queensberry Street,
North Melbourne, VIC 3051
Phone: (03) 9567 0777

Perth
Kwinana, WA 6966
Phone: 0427 517 359
P.O. Box 193
Kwinana, WA 6966

Sydney
Suite 2C, Centennial House
10 Ingleburn Road.
Ingleburn, NSW 2565
Phone: (02) 9618 5822
P.O.Box 327,
Ingleburn, NSW 2565