Model: 326 - In-Line Process Refractomer for Concentration / Density Measurements
Replaces Model: 614 (This model will be supported)

The LSC 326 process refractometer is the most universal instrument in our market sold throughout all industries.
Food, chemical, pulp & paper, etc.

Our Model 326 In-Line Refractometer is a fully computerized instrument which is a two-piece optical/electronic process instrument. It provides a continuous in-line concentration measurement, which can be viewed by the operator on its large 8.4" Touchscreen or remotely via an Ethernet connection on any computer in the factory network. The process can be automated using the standard Isolated, 4-20 mA output provided. A USB port allows for easy downloads of diagnostics and history files which can be sent to LSC for troubleshooting assistance.


The benefits of using LSC refractometers:
They provide the end-user with a tool that they can rely on 24/7/365. It allows the customer to ensure consistent end product. This is crucial for many different reasons which vary depending on which industry is utilizing our equipment. In the pulp & paper, the ability to control the process to their target point allows them to improve/streamline the entire Kraft process. This allows them to run at maximum energy efficiency which is critical considering the competitive global market we all work in.

In other industries like chemical / food / dairy / sugar production this is also true. However, more importantly is "Quality Control". Creating & maintaining brand loyalty is paramount and quality control provides "Quality Assurance". Product consistency every time it is purchased by your customers will help gain and control market share. Not to mention save money by reducing waste.

Model: 326 Brochure/Datasheet





Model: E-Net - Process Refractometer
when a SS Enclosure is required

Revolutionary is the most correct term to describe it. It will surely revolutionize the way customers view, utilize and interface with an In-Line Process Control Refractometer. Employing EtherNET as the communication, no unique protocol issues are encountered. All interaction is through any standard Web Browser on the customer's network (LAN), and/or DCS System.

For In-Line measurement and control of Concentration.... as % Solids / Brix / Refractive Index, or many other engineering terms, in all manufacturing industries.


Model E-Net Standard Brochure





Model 1022 - Failsafe Automatic "Black Liquor" Divert System
Full complied with "BLRBAC" Recommendation

The LSC Model 1022 Divert Sytem is a specialized piece of safety equipment which is designed specifically for the global "Pulp and Paper" market. We are happy to inform you that this is our 3rd generation divert system and that LSC was the 1st company to identify the need / provide a commercial solution for truly protecting recovery boilers since 1977. Since then we have been working closely with the experts of the industry, so that we can continue to be the leader in preventing smelt water explosions in recovery boilers.

The number one priority of the LSC 1022 Divert Sytem is to prevent a smelt water explosion. Therefore we have designed a package that contains two independent refractometers and one Black Liquor divert controller. This allows us to safely monitor the "Black Liquor Solids" at all times and if / when needed divert the black liquor away from the recovery boiler.

The LSC Model 1022 performs all necessary operational functions, including a number of "first ever" features, and fully complies with all recommendations of the Black Liquor Recovery Boiler Advisory Committee.

Precise user-friendly interface with on-screen prompting allows simple access to all information on the programming/diagnostic display located in the Stainless Steel enclosure.

Divert Controller's Responsibilities and Functions

  • Providing the divert output signal directly to the divert valve or to the burner management system.
  • Monitoring the "A" and "B" Refractometers Operation and Health
  • Automatically deciding dual or single refractometer operation
  • Self-diagnostic/trouble-shooting
  • Functional / Operational alarms
  • Setting / Event / History Memory

Smart Wash Technology - Prism Wash Logic
LSC is solely responsible for developing the benefit of Smart Wash. The CPU monitors both the A & B Sensors Prism Face as it washes every 20 minutes, at alternate 10 min. intervals, and controls the duration to wash for "only as long as necessary"... usually only 1 - 2 seconds. In the event a prism wash is not successful, another attempt is made shortly thereafter to clear the problem before an alarm is indicated. Note that when one sensor is being washed the other refractometer remains in service and is given full divert capability. Once the wash is over it will automatically go back to requiring both refractometers to initiate a divert. In all cases the 1022 is designed to be fail-safe!

Model 1022 Automatic Liquor Divert System Data Sheet



Gate Adaptor SAFETY Isolation Valve and Limit Switches

The LSC Gate Adapter Isolation Valve provides an ultimately Safe and Simple means to service the sensing head 24/7/365.

Our design slides a gate plate across the flow which does not pressurize the liquid between the sensing head and isolation valve. This allows your technicians to safely remove and service the refractometer from an active liquor pipeline. This dedicated safety valve eliminates the need for unsafe "By-Pass Loops", or an unscheduled liquor line shutdown to allow for maintenance. This is a major benefit that we are able to offer compared to other suppliers. A device of this type is specifically recommended by BLRBAC being specifically against by-pass-loops.

The Gate Adapter provides for an external lock whereby its inherent design "guarantees positive visual and physical indication of locked "fully-open" or locked "fully-closed". The lock cannot be employed if the Gate is less than 100 % opened or closed. Limit Switches allow for the divert controller to indicate closing of the gate adapter, automatically putting that unit out of service by going into "Single Unit Operation".






Pryde Measurement Pty. Ltd.,
ACN 112 029 777
National Customer Service - Free Call: 1800-688-211

 

Brisbane
Carole Park, QLD 4300
Phone: (03) 9567 0777
Melbourne
750 Queensberry Street,
North Melbourne, VIC 3051
Phone: (03) 9567 0777

Perth
Kwinana, WA 6966
Phone: 0427 517 359
P.O. Box 193
Kwinana, WA 6966

Sydney
Suite 2C, Centennial House
10 Ingleburn Road.
Ingleburn, NSW 2565
Phone: (02) 9618 5822
P.O.Box 327,
Ingleburn, NSW 2565