Pryde Measurement Pty Ltd - Meteorology
RETURN TO HOME

Barometric Pressure
Humidity and Temperature
Barometric Pressure





Model 270
Weather Data Systems Laser Interferometers
Altimeter Setting Indicators Transfer Pressure Standard
Engine Test Cells
  • Full Scale Pressure Output: 5.0 VDC
  • Zero Pressure Output: 0 VDCA
  • ccuracy: (RSS Method) ±0.05% Full Scale
  • Type of Pressure: Absolute,Gage,Barometric
  • Pressure Ranges: 0 to 10, 20, 50, 100 psia
  • 0 to 5, 10, 20, 50, 100 psig
  • 600 to 1100 hPa/mb
  • 800 to 1100 hPa/mb
  • Thermal Effects Compensated Range °F (°C):
    • 30 to 120 (-1 to 49)%FS/100°F(100°C)
    • max zero: ±0.2 (±0.36) hPa/mb %FS/100°F(100°C)
    • max span: ±0.2 (±0.36) hPa/mb%FS/100°F(100°C)
    • max zero: ±0.1 (±0.18) other ranges%FS/100°F(100°C)
    • max span: ±0.1 (±0.18) other ranges

Media Non-condensing air or gas compatible with aluminum, alumina ceramics, gold, fluorocarbon elastomer sealant and Buna-N O-Ring

Model 270 Data Sheet







Model 276
Weather and Environmental Data Logging
Clean Rooms Automotive Emissions
Altitude Applications
  • Full Scale Pressure Output 5.1 VDC, 4.5 for 5 VDC Excitation
  • Zero Pressure Output 0.1 VDC, 0.5 for 5 VDC Excitation
  • Accuracy: (RSS Method) ±0.25% Full Scale
    Type of Pressure: Barometric, Absolute
  • Pressure Ranges
    • 600 to 1100 hPa/mb
    • 800 to 1100 hPa/mb
    • 0 to 20 psia
  • Thermal Effects Compensated Range °F (°C):
    • 30 to 130 (0 to 55)%FS/100°F(100°C)
    • max.zero: ±1.0 (±1.8)%FS/100°F(100°C)
    • max.span: ±1.0 (±1.8)
  • Media Non-condensing air or gas compatible with stainless steel, alumina ceramics, gold, and elastomer sealant.

Model 276 Data Sheet




Model 278
Automatic weather stations
(AWS)
High accuracy barometric
pressure readings
Data loggers
  • Excitation 9.5 to 28VDC
  • Pressure Output 0 VDC to 2.5VDC, 0 to 5 VDC
  • Type of Pressure: Barometric
  • Pressure Ranges
    • 500 to 1100 hPa/mb, Accuracy +/- 0.6hPa/mb @ 20°C
    • 600 to 1100 hPa/mb, Accuracy +/- 0.5hPa/mb @ 20°C
    • 800 to 1100 hPa/mb, Accuracy +/- 0.3hPa/mb @ 20°C
  • Proof Pressure: 1500 hPa
  • Burst Pressure: 2000 hPa
  • Resolution: 0.01mb
  • Pressure fitting: 1/8" (ID dia.) Barbed fitting
  • Electrical Connection: 5-pin terminal block

Model 278 Data Sheet






Model 370
Barometric Pressure Monitoring Altimeter Calibration
Pressure Switch Setting Laser Interferometers
Min/Max Tracking Hi/Lo Alarming
Pressure Transfer Standard
  • Accuracy: (RSS Method) ±0.02% Full Scale
  • Digital Output Bi-directional RS-232 Interface
  • Type of Pressure: Barometric, Absolute
  • Pressure Ranges:
    • 600 to 1100 hPa/mb
    • 800 to 1100 hPa/mb
    • 0 to 10, 20, 50, 100 psia
  • Thermal Effects Compensated Range °F (°C):
    • 32 to 110 (0 to 45)%FS/100°F(100°C)
    • max.zero: ±0.2 (±0.4)%FS/100°F(100°C)
    • max.span: ±0.1 (±0.2)
  • Media Clean dry air or other gases (non-condensable)

Model 370 Data Sheet








Model 470

Automatic Weather Reporting Systems Barometric Pressure Compensation for the Wavelength of Laser Beams
High Accuracy Altimeter Altimeter Calibration
Weather Data Buoy Pressure Transfer Standard
  • Accuracy: (RSS Method) ±0.02% Full Scale
  • Digital Output: Bi-directional RS-232 Interface
  • Type of Pressure: Barometric, Absolute
  • Pressure Ranges:
    • 600 to 1100 hPa/mb
    • 800 to 1100 hPa/mb,
    • 0 to 10, 20, 50, 100 psia
  • Thermal Effects Compensated Range °F (°C):
    • 32 to 110 (0 to 45) %FS/100°F(100°C)
    • max.zero: ±0.2 (±0.4) %FS/100°F(100°C)
    • max.span: ±0.1 (±0.2)
  • Media Clean dry air or other gases (non-condensable)

Model 470 Data Sheet




Model: 470T
  • Digital pressure transducer
  • Accuracy: ± 0.02% FS at 21°C (70°F)
  • 500/600/800 to 1100 hPa/mb
  • 0 to 10, 20, 50, 100 psia
  • Excitation: DB-95 (9 Pin D-Subminiature Female) Pin: 3 GRD, 0 + 5 VDC
  • Output: RS232

Model: 470T Data Sheet






Humidity and Temperature


Rotronic Main Catalogue V17











MP102H/402H

MP102H & MP402H series probes provide truely class leading accuracy & stability. Based on the Hygroclip HC2-S3 probe, they provide linear voltage or current outputs for secure transmission over extended cable lengths. An RS485 interface is available on request.

Applications:

  • Weather stations
  • Snow guns
  • Building management systems

Highlights:

  • Range: 0 to 100%rH, -40ºC up to 100ºC
  • Current or voltage output signal
  • Optional: directly connected PT100 sensor
  • UART & service interface to PCB

MP102H/402H Data Sheet
MP102H/402H Manual
MP102H/402H Catalogue Page







HC2-S3

Applications:

  • Meteorology stations
  • Building automation systems
  • Agricultural Meteorology

Highlights:

  • Measures relative humidity, temperature & dew/frost point
  • Hygromer® V-1 sensor
  • Saves up to 2,000 measurement pairs (requires HW4 software)
  • Range : 0 to 100%rH / -50 to 100ºC
  • UART interface and freely scalable analog signals 0 to 1 V
  • Standard scaling 0 to 1 V = 0 to 100%rH / -40 to 60ºC
  • Probe with adjustment profile "standard", factory certificate

HC2 Probes Data Sheet
HC2 Probes Manual
HC2 Probes Catalogue Page







HC2-S3C03 / HC2-S3C03-PT15

New cable probe for agricultural and outside applications are equipped with a fast sensor and new filter technology which offers significant improved protection against growth of biofilm.

Applications:

  • Agricultural
  • OEM
  • Meteorology

Highlights:

  • Measures relative humidity, temperature & dew/frost point
  • Hygromer® V-1 sensor
  • Saves up to 2000 readings measurement pairs (requires HW4 software)
  • Range: 0 to 100%rH / -50 to 100ºC
  • UART interface and freely scalable analog signals 0 to 1 V
  • Standard scaling 0 to 1V = 0-100%rH / -40 to 60ºC
  • Probe with adjustment profile "standard", factory certificate

HC2 Probes Data Sheet
HC2 Probes Manual
HC2 Probes Catalogue Page



Actively Ventilated Shields

Applications:

  • Snow guns
  • Weather stations
  • Agricultural meteorology
  • Building management systems

Highlights:

  • Simple to install protective sheild with integrated fan
  • Special white coating minimises solar heating (RAL 9010)
  • Easy probe mounting
  • 12VDC or 24VDC supply for fan
  • compatible with various probe types

Ventilated Sheilds Data Sheet
Actively Ventilated Sheilds Manual
Ventilated Sheilds Catalogue Page






     
Naturally Ventilated Sheilds

*AC1004 has been discontinued, replaced by the AC1000
Same Specification as the AC1004 however now includes

  • Better air ventilation
  • Wall and pole mounting
  • Holds meteo probes HC2-S3 and HC2-S3C03

Applications:

  • Snow guns
  • Weather stations
  • Building management systems

Highlights:

  • East to install protective screen
  • Multi-plate system for natural ventilation
  • Simple probe mounting
  • Compatible with various probe types
  • Mounting hardware included
  • Suitable for 25 to 50mm mast diameters
  • Protection against wind speeds up to 68km/h and horizontal precipitation

Ventilated Sheilds Data Sheet
Ventilated Sheilds Catalogue Page









MP100A/400A

Standard meteorology probes with fixed sensors;
analog technology Hygromer® V-1 sensor

  • Precise & stable %rh & Temperature measurement
  • Specially designed for outdoor & meteorological measurements
  • Condensation resistant sensor
  • 0 to 1 V output signal(MP100) low power consumption
  • Cable length compensation up to 100m on voltage output versions
  • 4 to 20mA output options (MP400)
  • Proven in roadside & airport applications
  • Over 30,000 sold

Technical Data

  • Humidity sensor: Hygromer C94
  • Temperature sensor: Pt100/A
  • Range: 0 to 100%rh, -40. to 60ºC
  • Accuracy @ 23ºC: +/-1.5%rh, +/-0.3K
  • Long term stability: <1%rh, 0.1K per year typical
  • Response time: <15 seconds
  • Output signal:
    • MP106A:0 to 1V = 0 to 100%rh,ºC 4 wire Pt100 direct
    • MP103A:0 to 1V + 0 to 100%rh, -40 to 60ºC
    • MP408A:4 to 20mA + 0 to 100%rh, -40 to 60ºC
  • Output load:
    • MP106A/MP103A: min1000Ohm
    • MP408A: max 500Ohm
  • Power Supply:
    • MP106A/MP103A: 4.8 to 30VDC, 3.5mA(3/4wire), 6mA(5wire)
    • MP408A: 4.8 to 30VDC,50mA
  • Adjustment: potentiometer, 35, 80%rh, Hmin
  • Sensor protection: Wire mesh filter
  • Mechanical: White delrin probe with IP65 male connector
  • MP106A/MP103A 250 x 25mm Ø
  • MP408A 260 x 25mm Ø

MP100A Data Sheet
MP100A Manual
MP400A Manual
MP100A/400A Catalogue Page






Pryde Measurement Pty. Ltd.,
ACN 112 029 777
National Customer Service - Free Call: 1800-688-211

 

Brisbane
Carole Park, QLD 4300
Phone: (03) 9567 0777
Melbourne
750 Queensberry Street,
North Melbourne, VIC 3051
Phone: (03) 9567 0777

Perth
Kwinana, WA 6966
Phone: 0427 517 359
P.O. Box 193
Kwinana, WA 6966

Sydney
Suite 2C, Centennial House
10 Ingleburn Road.
Ingleburn, NSW 2565
Phone: (02) 9618 5822
P.O.Box 327,
Ingleburn, NSW 2565