CP11 Handheld Instrument
The CP11 handheld instrument is the latest development of an inexpensive multimeter that simultaneously measures and records CO2, humidity and temperature. It also calculates the dew point and wet bulb temperature. Equipped with the field-tested ROTRONIC HYGROMER® IN-1 humidity sensor, this instruments offers unbeatable value for money. Using the ROTRONIC HW4-Light software that comes with the device, it can be set as required and data can be downloaded, saved and analyzed.
Applications
- Indoor air quality
- monitoring in underground car parks (safety)
- Leak monitoring in filling plants (safety).
Features
- Measures and logs CO2, relative humidity and temperature
- Calculates the dew point
- Hygromer® IN-1 humidity sensor
- 18,000 data point memory for CO2, humidity and temperature values
- Maximum, minimum and average value display
- Adjustable audible CO2 alarm
- Display with backlight
- Adjustable auto power off function
- Mini USB interface
Software
- Supplied with the instrument or available as download SW2.1 (settings, data download, display of measured values) or compatible with optionally available HW4 software.
CP11 Datasheet
CP11 Quick Start Guide
CP11 Manual
|
|
|
|
CF3D / -Disp
Duct mount design for insertion into ducts and vents.
For ventilation control in residential properties, offices, classrooms, cinemas, public rooms, etc.
Features:
- Measurement range: 0…2,000 ppm
- Measurement technique: infrared (NDIR) with automatic calibration
- Accuracy: ±30 ppm
- Power supply: 16...29 VDC/AC
- Output 1 (0...2,000 ppm): 0…10 VDC
- Output 2 (0...2,000 ppm): 4…20 mA (no output 2 in CF3-W-EU(US)-Disp-FLI)
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: not necessary
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
|
|
|
|
CF3-W-EU / -Disp
Installed in the enthronement to be monitored and fits directly on standard EU surface-mounted boxes
For ventilation control in residential properties, offices, classrooms, cinemas, public rooms, etc.
Features:
- Measurement range: 0…2,000 ppm
- Measurement technique: infrared (NDIR) with automatic calibration
- Accuracy: ±30 ppm
- Power supply: 16...29 VDC/AC
- Output 1 (0...2,000 ppm): 0…10 VDC
- Output 2 (0...2,000 ppm): 4…20 mA (no output 2 in CF3-W-EU(US)-Disp-FLI)
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: not necessary
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
|
|
|
|
CF3-W-EU-Disp-FLI
Measures the CO2 concentration in rooms and emits an audible and visual alarm (fresh air indicator) when a value of 1,400 ppm is exceeded. Mute button on the side of the housing. Fits directly on standard EU surface-mounted boxes.
For ventilation control in residential properties, offices, classrooms, cinemas, public rooms, etc.
Features:
- Measurement range: 0…2,000 ppm
- Measurement technique: infrared (NDIR) with automatic calibration
- Accuracy: ±30 ppm
- Power supply: 16...29 VDC/AC
- Output 1 (0...2,000 ppm): 0…10 VDC
- Output 2 (0...2,000 ppm): 4…20 mA (no output 2 in CF3-W-EU(US)-Disp-FLI)
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: not necessary
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
|
|
|
|
CF3-W-US / -Disp
Installed in the enthronement to be monitored and fits directly on standard US surface-mounted boxes
For ventilation control in residential properties, offices, classrooms, cinemas, public rooms, etc.
Features:
- Measurement range: 0…2,000 ppm
- Measurement technique: infrared (NDIR) with automatic calibration
- Accuracy: ±30 ppm
- Power supply: 16...29 VDC/AC
- Output 1 (0...2,000 ppm): 0…10 VDC
- Output 2 (0...2,000 ppm): 4…20 mA (no output 2 in CF3-W-EU(US)-Disp-FLI)
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: not necessary
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
|
|
|
|
CF3-W-US-Disp-FLI
Measures the CO2 concentration in rooms and emits an audible and visual alarm (fresh air indicator) when a value of 1,400 ppm is exceeded. Red mute button on the front of the housing. Fits directly on standard US surface-mounted boxes.
For ventilation control in residential properties, offices, classrooms, cinemas, public rooms, etc.
Features:
- Measurement range: 0…2,000 ppm
- Measurement technique: infrared (NDIR) with automatic calibration
- Accuracy: ±30 ppm
- Power supply: 16...29 VDC/AC
- Output 1 (0...2,000 ppm): 0…10 VDC
- Output 2 (0...2,000 ppm): 4…20 mA (no output 2 in CF3-W-EU(US)-Disp-FLI)
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: not necessary
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
|
|
|
|
CF5-D / -Disp
Instvlled in the climate zone.
For Ventilation control in residential rooms, offices, classrooms, cinemas, etc.
Features:
- Measurement range CO2: 0…3,000 ppm / temperature: 0…50 °C / 30...120 °F
- Measurement technique: infrared (NDIR) with automatic calibration
- Accuracy: ±30 ppm
- Power supply: 16...29 VDC/AC
- Output 1 (0...2,000 ppm): 0/2…10 VDC or 0/4…20 mA
- Output 2 (0...50 °C): 0/2…10 VDC or 0/4…20 mA
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: not necessary
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
CF5 Manual
|
|
|
|
CF5-W / -Disp
Installed in the climate zone.
For ventilation control in residential rooms, offices, classrooms, cinemas, etc.
Features:
- Measurement range CO2: 0…3,000 ppm / temperature: 0…50 °C / 30...120 °F
- Measurement technique: infrared (NDIR) with automatic calibration
- Accuracy: ±30 ppm
- Power supply: 16...29 VDC/AC
- Output 1 (0...2,000 ppm): 0/2…10 VDC or 0/4…20 mA
- Output 2 (0...50 °C): 0/2…10 VDC or 0/4…20 mA
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: not necessary
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
CF5 Manual
|
|
|
|
CF8-D/W-IN
Model IN (Incubator) is suitable for measurements in incubators or climate chambers.
For ventilation control in incubators and environmental chambers
Features:
- Model: IN (Incubator)
- Measurement range CO2: 0…3 %vol (0…30,000 ppm)
- Accuracy CO2: ±200 ppm
- Output 1 (0...3 %vol CO2): 2...10 VDC or 4...20 mA
- Output 2 (0...2 %vol CO2): 0...5 VDC or 0...10 mA
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Maintenance: is not necessary for indoor applications. Industrial applications may require annual calibration.
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
CF8-D/W-IN Manual
|
|
|
|
CF8-W-Disp-AL
Model AL (Alarm) is equipped with two relays that can be connected to an alarm system. It measures CO2 in very high concentrations.
For ventilation control in underground garages, transport/storage, vehicle terminals, tunnels, etc...
Features:
- Model : AL (Alarm)
- Measurement range CO2 : 0…4 %vol (0…40,000 ppm)
- Accuracy: ±200 ppm
- Output 1: (0...4 %vol) 0/2…10 VDC or 0/4…20 mA
- Output 2: (0...4 %vol) 0/2…10 VDC or 0/4…20 mA
- Output 3 (CO2): Relay 1: open <1.4 %, closed >1.5 %
- Output 4 (CO2) Relay 2: open <2.9 %, closed >3.0 %
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Communication: MODBUS
- Maintenance: Is not necessary for normal indoor applications. Certain industrial applications require annual calibration.
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
CF8-W-Disp-AL Manual
|
|
|
|
CF8-W-Disp-CO
Model CO (Carbon Monoxide) is suitable for closed rooms in which a combustion process takes place.
For monitoring of carbon monoxide and carbon dioxide in underground garages, tunnels, mines, latrge halls, with relays for CO2 and CO alarm systems.
Features:
- Model: CO (Carbon Monoxide)
- Measurement range CO2: 0…3,000 ppm
- Measurement range CO: 0…100 ppm
- Accuracy CO2: ±30 ppm
- Accuracy CO: ±10 ppm
- Output 1 (0...100 ppm CO): 0/2…10 VDC or 0/4…20 mA
- Output 2 (0...2,000 ppm CO2): 0/2…10 VDC or 0/4…20 mA
- Output 3, relay open >35 ppm (CO) and >1'500 ppm (CO2) , closed <30 ppm (CO) and <1'400 ppm (CO2)
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Communication: MODBUS, RS-485 (optional)
- Maintenance: is not necessary for indoor applications. Industrial applications may require annual calibration.
- Lifetime: >5 years (limited by the CO probe)
CO2 Transmitters Datasheet
CO2 Catalogue Pages
CF8-W-Disp-CO Manual
|
|
|
|
CF8-W-Disp-GH
Model GH (Greenhouse) is equipped with an extra dust and water filter and is suitable for adverse ambient conditions.
For ventilation control in greenhouses and harsh environments.
Features:
- Model : GH (Greenhouse)
- Measurement range CO2: 0…4 %vol (0…40,000 ppm)
- Accuracy: ±200 ppm
- Temperature measurement range: 0…50 °C (30...120 °F)
- Output 1 (0...4 %vol): 0/2…10 VDC or 0/4…20 mA
- Output 2 (0...50 °C): 0/2…10 VDC or 0/4…20 mA
- Output 3 (CO2): Relay 1: open <1.9 %, closed >2.0 %
- Range of application: 0…50 °C (30...120 °F) / 0…95 %RH
- Communication: MODBUS
- Maintenance: is not necessary for normal indoor applications.Certain industrial applications require annual calibration
- Lifetime: >15 years
CO2 Transmitters Datasheet
CO2 Catalogue Pages
CF8-W-Disp-GH Manual
|
|