DF-700 Series - Moisture Analysers







DF-745SG
Trace Moisture Analyser

The DF-745SG Trace Moisture Analyser brings the extraordinary capabilities of the DF-700 Series analysers to applications in the specialty gas industry as well as allied applications requiring the accurate measurement of trace moisture levels in gas mixtures. This combination of high sensitivity-100ppb LDL-with broad range -100ppm- at an attractive price means that high-value specialty gas operations can now be controlled to ensure high yields economically with a DF-745SG analyser.

The DF-745SG is a sophisticated process analyser that has application software specifically designed for blending specialty gases involving single gases and mixtures with up to eight components drawn from a database of 13 standard background gases. The user can pre-define gas mixture templates for routine blends (with up to 30 templates) or define a custom mixture using the front control panel. The analyser allows the user to add custom gases to the database using a simple data collection procedure. The analyser collects production data that identifies the components and volumes in a mixture as well as the date, time and moisture content of the blend. This data can be displayed on the analyser’s data screen or downloaded onto a USB drive and printed out as a report in an Excel format.

The DF 745SG is a versatile tool for help in minimizing the moisture in your specialty gas stream. The analyser is designed for 19 inch rack mount as a fixed system and, at only 64 lbs, is ideal for cart or other mobile applications. The analyser can be quickly moved from port to port thanks to isolation hardware and software routines that virtually eliminate long dry down times often associated with these applications.

Based on the same proven design tradition as Delta F's oxygen and moisture instruments the DF-745SG expands the range of applications that can now afford this capable technology.

Unsurpassed Capability and Performance

  • 100ppb sensitivity with very high accuracy
  • 100ppb low detection limit (LDL)
  • No field calibration necessary
  • A wide dynamic range from 0.1ppm to 100ppm (linear)
  • An ambient operating temperature range from 10 to 40ºC
  • Fast speed of response, <10 minutes to reach 90% of an upward step challenge
  • Fast upset recovery, <5 minutes to recover from high ppm upset to within 1 ppm of previous stable reading

DF-745SG Datasheet






DF-730
NanoTrace Moisture in HCl Analyser
  • LDL of 1 ppb
  • Accuracy the greater of ±5% of reading or 0.1 ppb
  • Upset recovery time of <15 minutes

DF-730 Datasheet






DF-740
NanoTrace Moisture in Ammonia Analyser
  • Simple to use instrument for the measurement of trace levels of moisture in ammonia
  • Designed for long term unattended operation with minimal maintenance.
  • LDL of 10 ppb, excellent linearity, fast response

DF-740 Datasheet







DF-745
Trace Moisture Analyser

The DF-745 Trace Moisture Analyser brings the extraordinary capabilities of the DF-750 to applications in the petrochemical industry as well as the traditional Ultra Pure Gas industry group. This combination of high sensitivity-2ppb LDL-at an attractive price means that high-value petrochemical and semiconductor processes can now be controlled to ensure high yields economically with a DF-745 instrument.

The DF-745 is a sophisticated process analyser and a versatile tool for minimizing the moisture in your process stream. The analyser is designed for 19 inch rack or panel mount and, at only 64 lbs, is ideal for cart or other mobile applications. The analyser can be quickly moved from port to port thanks to intricate hardware and software routines that virtually eliminate dry down times often associated with these applications.

Based on the same proven design tradition as Delta F's oxygen and moisture instruments the DF-745 expands the range of applications that can now afford this capable technology.

Unsurpassed Capability and Performance

  • 500 ppt sensitivity with very high accuracy
  • 2 ppb low detection limit (LDL)
  • No field calibration necessary
  • A wide dynamic range from .002ppm to 20 ppm (linear)
  • An ambient operating temperature range from 10 to 40ºC
  • Fast response time with initial dry down time of <12 hours to 20 ppb and 16 hrs to 10 ppb
  • Fast clean-up time with upset recovery from high ppb levels to within 10 ppb of previous stable reading within 5 minutes

DF-745 Datasheet







DF-750
NanoTrace Moisture Analyser

The DF-750 NanoTrace Moisture Analyser pushes the boundaries of moisture analysis technology. Using revolutionary Tunable Diode Laser Absorption Spectroscopy (TDLAS), the DF-750 delivers part-per trillion (ppt) capabilities for a range of applications in semiconductor fabrication and UHP gas measurements. The analyser easily fits into a 19" rack and is ideal for mobile carts. With its internal isolation capability so that you can move the analyser from port to port without incurring any dry-down time. And, like Delta F's world-renowned oxygen analysers, it provides results that are consistent and reliable over a long instrument life cycle.

Unsurpassed Accuracy and Performance

The 700 Series uses laser absorption spectroscopy to identify and "count" the water molecules in a gas sample as it flows through the instrument. Since its fundamental design is based upon Beer's Law, the 700 Series can perform ultra trace moisture determinations and does not require field calibration. In addition, the TDLAS technology delivers:

  • 100 ppt sensitivity with very high accuracy
  • 200 ppt LDL
  • No field calibration necessary
  • A wide dynamic range from 100 ppt to 10 ppm (linear)
  • An ambient operating temperature range from 10 to 40ºC
  • Fast response time with an initial dry down time of <24 hours to 5 ppb
  • Fast clean up time with upset recovery from ppm levels in minutes

DF-750 Datasheet



DF-760E
NanoTrace Dual Moisture and O2 Analyser
  • Only instrument that combines industry standard O2 analysis with high accuracy and performance TDLAS moisture analysis
  • Analysis of O2 and moisture to ppt levels in a single unit
  • Rapid response
  • Inert cathode immune to damage from trace levels of acids or hydrocarbons
  • Non-depleting anode - no drifting and no frequent calibrations

DF-760E Datasheet





DF-100 Series - Analogue-Base Analysers



DF-110E

The DF-110E offers a flexible and cost-effective way to include superior oxygen analysis in your OEM system. The DF-110E is calibrated to standards traceable to NIST and operated for several days to ensure flawless performance out-of-the-box. Depending on the application, the sensor can operate for years without recalibration and requires only the occasional addition of distilled water for maintenance.

  • Instantaneous response to oxygen change- less than 10 seconds to read 90% of a step change
  • Flexibility - put together the exact configuration you need to include in your system
  • Performance - the analyser is delivered ready to use
  • Low/No Maintenance - no recalibration - no sensor replacement necessary
  • STAB-EL™ option eliminates acid scrubbing for trace level measurements

DF-110E Datasheet





DF-140E

The DF-140E allows for reliable oxygen measurement in a wide variety of environments, including outdoors and in explosive environments with a NEMA 7 remote sensor enclosure. Using the revolutionary non-depleting E-Sensor, the DF-140E delivers reliable readings without frequent recalibration and periodic sensor replacement.

  • Long term reliability and stability
  • Durability – can be used in Class I, Division 1 or 2 areas
  • Low/No maintenance
  • STAB-EL™ option allows for accurate measurement in the presence of acid gases

DF-140E Datasheet





DF-150E

Every DF-150E is custom configured under ISO-9001 controls to your precise specifications and calibrated to standards traceable to NIST and operated for several days to ensure flawless performance. The ultra-stable E-Sensor can operate for years without re-calibration giving you a long and useful life.

  • Maximum configuration flexibility – build it the way you need it
  • Superior performance out-of-the-box
  • Accurate - ±3% of reading or 0.5% of measurement range
  • Instantaneous response to oxygen change
  • Fast response – typically less than 10 seconds to read 90% of a step change

DF-150E Datasheet





DF-300E Series - Microprocessor-Based Analysers




DF-310E

The DF-310E with the E-Sensor is ready to handle your oxygen analysis needs in almost any application.

  • Accuracy – the greater of ±3 reading or ±0.02% range
  • Ranges from 0-0.5ppm to 25%Instantaneous response to oxygen change
  • Fast response – typically less than 10 seconds to read 90% of a step change
  • Background gas compatibility including N2, H2, Co, freons, hydrocarbons, and more
  • STAB-EL™ option removes acids and ionic impurities from the electrolyte that could affect sensor performance
  • Optional battery back-up for extended use and process protection

DF-310E Datasheet






DF-320E

The DF-320E brings improved performance to harsh and hazardous environments.

  • Class I, Div 2, Groups A,B,C,D, CSA and CENELEC Zone 2 certification
  • Perfect for any application where potential explosion is a possibility – for example in natural gas lines or LNG storage, etc.

DF-320E Datasheet






DF-340E

The DF-340E is tough and durable - protected by a dustproof, waterproof, explosion proof, enclosure, they also offer the option of remoting the sensor in a Nema 4 enclosure.

  • NEMA 4 version of the DF-310E
  • Ideally suited for harsh environments
  • Sensor and flowmeter can be mounted in the analyser enclosure or remoted in a Nema 4 enclosure.

DF-340E Datasheet








DF-370E

The DF-370E is tough and durable - protected by a dustproof, waterproof, explosion proof, enclosure, they also offer the option of remoting the sensor in a Nema 7 enclosure.

  • Nema 7 version of the DF-310E
  • Sensor and flowmeter aremounted in a remote Nema 7 enclosure.

DF-370E Datasheet




DF-500E Series - Premium performance for the semiconductor (UHP gas) industry





DF-550E

The NanoTrace provides a reliable LDL of 200 ppt in a compact, easy-to-use analyser

  • Superior performance for dependable measurements
  • Low maintenance with very low drift for infrequent recalibration
  • Selection of configurations, including initiation via front panel or digital interconnect, hand carry portable option

NanoTrace provides a reliable Low-detection-level of 200 ppt in a compact, easy to use analyser. The superior NanoTrace performance has been verified by a host of independent third parties such as Air Products and Chemicals Inc. Part of the extensive APIMS testing is shown. Every NanoTrace is manufactured under ISO 9001 control and is calibrated and operated for five weeks to ensure a fast and accurate start-up at your site.

Superior Performance

  • The low LDL provides a large "Analytical Headroom" for dependable measurements.
  • Fast response provides sensitive and dependable process monitoring.
  • Quick upset recovery avoids "running blind" when process problems occur.

Low Maintenance
Very low drift makes the need for frequent calibrations unnecessary. The zero purifier is used only for calibration and not to scrub the electrolyte as is common in other analysers. Expensive and disruptive purifier replacements are not required.

Selection of Configurations
The Automatic Calibration System can be initiated at the front panel or via digital interconnect. The Manual Calibration system can be included for "hand carry", portable operation. The NiCad Battery and Isolation Valve options enable truly portable operation.

DF-550E Datasheet







DF-560E

The NanoTrace II provides the lowest detection level (LDL) in the industry

  • Ultimate analyser performance - very stable 75 ppt LDL in an industrial low maintenance analyser
  • Automated maintenance on a scheduled basis keeps it up and running accurately
  • Automated data logging with 4 day and 30 day graphical records of analyser readings

NanoTrace II provides the lowest LDL in the industry.Part of the extensive APIMS testing by several third parties, including SAES Pure Gas Inc., is shown. NanoTrace II is an extension of the first NanoTrace used in semiconductor fabs and analytical carts around the world. It features a lower LDL, Data Graphing, Scheduled Automatic Calibrations, Automated Maintenance Logging, and a variety of other new capabilities. Every NanoTrace is manufactured under ISO 9001 control and is calibrated and operated for five weeks to ensure a fast and accurate start-up at your site.

The Ultimate Analyser Performance

  • Very stable 75 ppt Low-Detection-Level in an industrial, low maintenance analyser
  • Automated Maintenance
  • Executes automatic zero and span calibrations on a scheduled basis, or executes scheduled automatic "checks" and issues a notice when calibration is needed.
  • Automatic Maintenance Log records water additions, sensor data, and calibration activity to ensure good analytical practice and ISO record-keeping requirements.

Automated Data Logging

  • Builds 4 day and 30 day graphical records of analyser readings.
  • A "Zoom" feature provides a close look at data anywhere in the long term record.
  • Select "Fill and Stop" or "Continuous" data collection modes.

DF-560E Datasheet








Pryde Measurement Pty. Ltd.,
ACN 112 029 777
National Customer Service - Free Call: 1800-688-211

 

Brisbane
Carole Park, QLD 4300
Phone: (03) 9567 0777
Melbourne
750 Queensberry Street,
North Melbourne, VIC 3051
Phone: (03) 9567 0777

Perth
Kwinana, WA 6966
Phone: 0427 517 359
P.O. Box 193
Kwinana, WA 6966

Sydney
Suite 2C, Centennial House
10 Ingleburn Road.
Ingleburn, NSW 2565
Phone: (02) 9618 5822
P.O.Box 327,
Ingleburn, NSW 2565