SERVOTOUGH OxyDetect
SERVOMEX OxyDetect is revolutionary because its sensor never depletes.
And, unlike electrochemical-based detectors, it never gives false alarms, potentially saving you thousands in downtime every year.
- For integration into gas detection systems
- paracube®micro sensor never needs replacing saving electrochemical sensor replacement costs per year
- No loss of reliability means no more false alarms, potentially saving you $$$$ a year - False alarm evacuations cause lost time and production
- Optional five-year warranty, including the sensor
- Easy to use digital interface
- Range 0-25% Oxygen
- Accuracy: ±0.2%O2
- Drift : <0.2% per month
- Pressure effects per 1% change in ambient pressure: <0.04%O2
- Isolated 4-20mA
- Fault alarm via jam to 0mA advanced microprocessor based diagnostics
- Power: 24Vdc
SERVOTOUGH OxyDetect - Expert Paper
|
|
|
|
SERVOTOUGH 1800
Oxygen Analyser
The 1800 is a stable, accurate and highly specific oxygen analyser for safe area use. It is designed to reliably measure percent oxygen in many safety critical industrial applications.
- Designed for safe area oxygen analysis
- Low maintenance and re-calibration requirements
- Special version for solvent bearing samples
- Range of alarm outputs to aid integration with other systems
- Easy to set up and operate
Features:
- Fast response
- Low cross sensitivity to background gases
- Extremely low drift
- Isolated 4-20mA analogue output
- Concentration, range indication and flow fail alarm relay outputs
- Reliable analogue based electronics
- Solvent vapour tolerant version available
- Weatherproof enclosure
Typical Applications:
- Ambient air monitoring
- Gas cylinder storage
- Safety inerting monitoring
- Marine inerting applications
SERVOTOUGH 1800 Data Sheet
|
|
|
|
SERVOTOUGH Oxy
1900 Hazardous Area Oxygen Analyser
The 1900 is a stable, accurate and highly specific oxygen analyser for hazardous area use. It is designed to reliably measure percent oxygen in many safety critical industrial applications.
- Designed for hazardous area oxygen analysis (ATEX Category 2 / Zone 1 /- Class 1 Div 1)
- Low maintenance and re-calibration requirements
- Special version for solvent bearing samples
- Range of alarm outputs to aid integration with other systems
- Calibration possible without need for 'Hot Work Permit'
Features:
- Fast response
- Low cross sensitivity to background gases
- Suitable for ATEX Category 2 / Zone 1 / Div1 hazardous areas
- Suitable for use with flammable samples
- Isolated 4-20mA analogue output
- Concentration, range indication and flow fail alarm relay outputs
- Reliable analogue based electronics
- Solvent tolerant version available
- Weatherproof enclosure
Typical Applications:
- Pharmaceutical - centrifuge blanketing/inerting
- Petrochemical process control
- Solvent recovery
- Marine terminal monitoring
SERVOTOUGH Oxy Data Sheet
|
|
|
|
SERVOTOUGH Spectra
1900IR Hazardous Area Infra-Red Analyser
The newly styled 1900IR Intrinsically Safe Gas Analyser is a single component, zone 1 hazardous area gas analyser with no purge required.
- Suitable for measuring % levels of Carbon Dioxide.
- Highly accurate with fast speed of response and excellent drift and repeatability characteristics.
- All sensors use non-depleting technologies, maximizing availability and reducing maintenance and operating costs.
Technology Used:
- Carbon Dioxide, Single beam, single wavelength infrared technology using Servomex patented long life source gives a highly stable, selective and low maintenance measurement.
Features:
- Infrared sensors give reliable, accurate results with low maintenance and running costs
- Suitable for use with flammable and toxic samples
- ATEX Certified as: Ex II 2G Ex ia d IIC T4
- IEC Ex Certified as: Ex ia d IIC T4
- Rugged, robust IP65 construction
- Digital interface developed with customers to ensure desirable functions and ease of use
- White backlit LCD Display
- Single 4-20mA output and 4 Relay Outputs
Typical applications:
- Natural Gas pipelines, scrubber efficiency, blending
- GTL syngas production
- Refineries, catalytic regeneration
- HYCO, process control, efficiency
- Ethylene Plants, catalytic regeneration, scrubber efficiency
SERVOTOUGH Spectra Data Sheet
|
|
|
|
SERVOTOUGH OxyExact
2200 Hazardous Area Oxygen Transmitters (up to 6)
The 2200 is specifically designed to measure oxygen in process control applications.
- Unrivalled accuracy, reliability, stability and repeatability
- Low installation cost
- Low cost of long-term ownership
- Ease of use
- Suitable for ATEX Category 2 / CENELEC Zone 1 / FM Division 1 / FM Zone 1 use
- Servomex 2223 - ATEX Category 2 / FM Division 1 Hazardous Area Oxygen Transmitter
- Servomex 2210 - ATEX Category 3 / FM Division 2 Control Unit
- Servomex 2213 - ATEX Category 2 / FM Division 1 Control Unit
Features:
- Transmitter unit:
- 0 -100% range with 0.01% accuracy (minimum range 0 - 0.5%)
- Intrinsically safe 0/4-20mA output
- Three status relay contacts (NAMUR Contacts)
- Two 4-20mA inputs for cross interference and external pressure compensation
- Two flow sensor inputs
- Internal Flow Alarm option
- Control Unit:
- Bright digital display reading 0-100% 02 with 0.001% resolution
- Full autocalibration and validation facilities
- Digital communications
- Multi language capabilities
- Full diagnostic and status indicators:
- Up to six transmitters can be connected to a single control unit
Typical Applications:
- Oxidation control reactions
- EO, PTA, EDC
- Catalyst regeneration
- Hydrogen and chlorine production
SERVOTOUGH OxyExact Data Sheet
|
|
|
|
SERVOTOUGH SpectraExact
2500 Process Gas Analysers
The 2500 series of photometric process analysers offer single or dual component gas analysis to suit virtually any process, combustion or emissions gas analysis application. They are designed for industrial environments with the emphasis on rugged construction, high performance and simple operation.
- On-line, real time process analysis
- High reliability, accuracy and stability
- Low cost of ownership and long maintenance intervals
- Single & multi-component analysis capability
- Easy integration with DCS and other control systems
- Suitable for field mounting in hazardous area locations
Features:
- Hazardous area certification (CENELEC Zone 1 and 2, FM Class 1 Division 2)
- Measures corrosive, toxic and flammable sample streams
- Simple operation, easy maintenance, comprehensive diagnostics
- Full user facilities including password protection and real-time clock, with historical data logs
- Two mA outputs, 3 relay outputs, all user assignable
- Optional additional mA and relay outputs available
- IP65 ingress protection
Typical Applications:
- The 2500 series analysers are highly flexible and can be configured to suit virtually any process environment.
Measurements include:
- Water in EDC
- Carbon dioxide
- Ethylene
- Acetylene
- Sulphur dioxide
- Chlorine
SERVOTOUGH SpectraExact Data Sheet
|
|
|
|
SERVOTOUGH Fluegas
2700C Combustion Gas Analyser
The 2700 measures oxygen and combustibles in flue gases to allow improved combustion efficiency and reduced emissions. The 2700 gas analyser is designed to suit the most demanding needs of combustion efficiency applications in the Power Generation and Process Industries
- Continuous measurement of Oxygen and / or combustibles
- Simple to operate and install
- Fully field maintainable
- 0-500 ppm(v) Combustibles (COe) measuring range
- Suitable for high temperature operation up to 1750°C (3182°F)
Servomex's innovative Thick Film Calorimetry (Tfx) cell allows a user to make a sensitive combustibles analysis rather than a breakthrough indication. This gives even more precise control of the process which results in greater fuel savings and lower emissions.
Features:
- Backlit LCD display, with easy to use software
- Autocalibration facility and utilities panel
- Blowback facility
- Control unit certified for non-hazardous or ATEX Category 3 or FM Class 1, Div 2
- 4" ANSI 150lbs flange as standard with adaptors to suit other flange types
- Sensor head mounting options include:
- Probe retention
- Thermal spacer
- Stand off flange
- Combined thermal spacer & probe retention
- Combined probe retention & stand off flange.
- Available with stainless steel, high temperature alloy or ceramic probes with filter options for high dust loading applications.
Typical Applications:
- Process heaters
- Utility boilers
- Thermal crackers
- Iron & steel
- Incinerators
SERVOTOUGH Fluegas Data Sheet
|
|
|
SERVOTOUGH Laser (2900)
SERVOTOUGH LaserCompact (2940)
SERVOTOUGH LaserExact (2950)
SERVOTOUGH LaserSP
|
SERVOTOUGH Laser (2900)
The SERVOTOUGH 2900 is a series of high performance cross stack monitors designed for a variety of emissions monitoring and process control applications in a diverse range of industries.
The 2900 analysers are distributed by Servomex on behalf of NEO Monitors AS. Please contact us for a full list of countries where we can supply the 2900.
- Continuous in-situ monitoring
- Low detection limits
- Response times down to one second
- No direct cross interference to other gases
- Utilising the proven tunable diode laser (TDLAS) measurement technique
- High temperature and high pressure operation possible
- Suitable for high dust applications
- Ethernet connectivity option
- Low cost of ownership
Technology Used:
- The following instrument configurations are available in the 2900 product line:
- Single Path monitor
- Single Path compact
- Open Path monitor
- Multipass monitor
SERVOTOUGH Laser(2900) Data Sheet
SERVOTOUGH LaserCompact(2920) Data Sheet
SERVOTOUGH LaserCompact(2940) Data Sheet
SERVOTOUGH LaserExact(2950) Data Sheet
SERVOTOUGH LaserSP Data Sheet
|
|
|
|
SERVOTOUGH SpectraScan
The SERVOTOUGH SpectraScan Tunable Filter I.R. Analyser is an infrared absorption-based on line monitoring system, configured for measurement of light hydrocarbons (alkanes, alkenes and alkynes). A real-time optical analyser, the SERVOTOUGH SpectraScan is capable of accurately separating hydrocarbon components, a process which could previously only be performed by gas chromatograph (GC) analysers.
- Real-time operation to sub-second update rates
- C1C5+ hydrocarbon separation and total gas analysis
- Continuous flow-through analysis
- Remote, unattended continuous operation
- Eliminates carrier gases and other consumables
- Permanent span calibration for industrial deployment
- Virtually zero cross-sensitivity and high sensitivity
Technology Used:
Spectroscopic Advanced NIR/IR absorption spectroscopy utilises state of the art spectral scanning and chemometric based data processing for exceptionally high accuracy, low cross sensitivity and a very fast speed of response. A flow-through cell utilises a patented spectrometer design for a highly stable and accurate measurement; an advanced Tuneable Filter Spectroscopy Analysis Algorithm delivers industry-leading interference compensation with a permanent span calibration, low cross-interference, high baseline stability and a linear response.
Features:
- Simultaneous scanning of selected wavelength bands for gases including Methane, Ethane, Propane, iso-Butane, n-Butane, Propylene and Ethylene.
- Unique wavelength-sweeping tuneable filter spectrometer enables sub-second update rates for C1-C5+ analysis.
- Robust and reliable design, the instrument’s optimised design produces very low zero and span drift, with minimal validation times
- Fixed hardware configuration ensures low maintenance costs
- No carrier gas ensures minimal installation infrastructure requirements
- Available as 19” rack mounted general purpose unit and wall mounted safe area version certified to CSA CL1 Div2 and ATEX Zone 2.
- MODBUS over TCP/IP with Ethernet port
- Optional Local display and 4-20mA outputs
Typical Applications:
- BTU/Wobbe content measurement
- Natural gas quality and composition
- Fuel blending and control
- Gas turbine, engines, fuel cells
- Alternative (biogas, syngas) fuels
- LNG production and custody transfer
- Hydrocarbon speciation applications
SERVOTOUGH SpectraScan Data Sheet
|
|
|
|
SERVOPRO Chroma (k4000)
Trace Gas Analyser
The SERVOPRO Chroma (K4000) analyser with its unique non-depleting plasma emission detector is one of the most versatile gas analysers on the market. Many applications will be satisfied by a single 4U rack analyser configuration, making the SERVOPRO Chroma a compact, cost effective solution.
- Trace gas measurement ppb/ppm
- Stand-alone system , no need for third party software
- PlasmaHC hydrocarbon system measurement does not use a FID
- ArgonSep separates argon without use of oxygen scrubber
Technology Used:
- Plasma Emission Detector - Servomex's unique non-depleting plasma emission cell offers a fast, accurate, selective, and sensitive response.
- PlasmaHC - measures methane and THC without the use of a FID, eliminating the need for maintenance and fuel.
- ArgonSep - separates Argon completely from oxygen without the need for oxygen scrubbers, providing a sensitive, maintenance free measurement.
Features:
- Ethernet connectivity for remote control and monitoring
- 4-20 mA outputs for peak impurity values and chromatogram signal
- Remote range I.D. contact per impurity
- Cabinet temperature regulation to minimise temperature drift (ambient temperature range from 15 to 35ºC)
Typical Applications:
- Air separation plants
- Argon purification plants
- Cryogenic truck loading station
- Hydrogen purification plants
- Speciality gas laboratories
- Semiconductor plants
- Helium liquification plants
SERVOPRO Chroma Data Sheet
|
|
|
|
SERVOPRO FID
Process Analyser
The SERVOPRO FID is a Flame Ionization Detector based analyzer designed to assure safe operation within Cryogenic Air Separation plants by assuring the level of Total Hydrocarbons (THC) is maintained below inflammable limits as well as provide quality control in pure O2, N2, Ar, and Air.
- Low fuel consumption reduces cost of operation
- Remote communication capability ideal for unmanned plants
- Excellent output resolution over 3 operating ranges
Technology Used:
- A Flame Ionization Detector (FID) burns hydrocarbons present in a sample to produce charged molecules which causes electrical conduction between 2 electrodes. The detector measures the conduction of charged particles and produces an output which is directly proportional to the concentration of Total Hydrocarbons (THC) in the sample.
Features:
- Reliable, Stable Flame Ionization Detector
- Standard factory set 3 measuring ranges with over range
- Automatic range change
- Flame out alarm and fuel shut off valve
Typical Applications:
- Inlet and Low Pressure Column in Air Separation Plants for Safety
- Truck filling stations and product pipelines for quality control of O2, N2 and Ar
- Cylinder filling stations for quality control of O2, N2 and Ar
SERVOPRO FID Data Sheet
|
|
|
|
SERVOPRO MonoExact
The SERVOPRO MonoExact TCD is designed to meet the process control and product qualification needs of industrial gas producers and users. Offering our ground breaking TruRef Thermal Conductivity measurements, its performance surpasses other katharometer based TCD analysers.
- Easy to set up and operate
- Low maintenance
- Extremely stable and reliable sensor
- Eliminates Thermal Convection effects
- RS232/RS485 serial data output
- Modbus, Profibus, Ethernet communications
Technology Used:
- Argon in Oxygen, Nitrogen in Air Thermal conductivity measurement using the patented "TruRef" technology
- Nitrogen in Argon Thermal conductivity measurement using the patented "TruRef" technology
Features:
- Half 19” rack footprint for benchtop, panel on 19” rack mounting
- Can fit two MonoExact analysers in one 19” rack slot
- Two level flow alarm
- Digital communications - Modbus, Profibus and Ethernet
- Alarm, fault and calibration history logs
- Auto-validation facility
Typical Applications:
- Product purity on air separation plant
- Process control on air separation plant
- Bottling/filling plant applications
SERVOPRO MonoExact Data Sheet
|
|
|
|
SERVOPRO MultiExact
Process Analyser
The SERVOPRO MultiExact is designed to meet the process control and product qualification needs of industrial gas producers and users.
- Easy to set up and operate
- Low maintenance
- Extremely stable and reliable sensors
- Can measure up to two gases simultaneously
- RS232/RS485 serial data output
- Modbus, Profibus, Ethernet communications
Technology Used:
- Oxygen purity measurement Servomex’ unique paramagnetic cell, which offers a fast, linear, accurate, highly stable and selective response in a non-depleting rugged package.
- Oxygen at trace levels - Servomex’ unique zirconia cell, which offers an accurate and stable measurement in a design that gives a fast response and exceptionally long service life.
- Carbon dioxide, nitrous oxide, carbon monoxide* and methane* at trace levels Single beam gas filter correlation photometric technology, which gives a highly stable, sensitive and selective measurement.
Features:
- Simultaneously measures up to 2 gas streams
- Paramagnetic sensor with temperature control and pressure compensation for ultimate performance
- Independent autovalidation/ calibration of measurements with option of integrated stream switching valve block
- Alarm, fault and calibration history logs
- Bench top, panel or 19” rack mount
Typical Applications:
- Product purity on air separation plant
- Process control on air separation plant
- Monitor the trace CO2 on scrubbed air inlet to air separation process
- Bottling/filling plant applications
SERVOPRO Multiexact Data Sheet
|
|
|
|
SERVOPRO Plasma (k2001)
Process Analyser
The SERVOPRO Plasma is designed for continuous monitoring of nitrogen in argon, helium or both. Its unique plasma emission detector provides an accurate, highly stable and reliable measurement. It uses a new micro-processor platform that offers enhanced connectivity, allowing you to remotely control the analyser from anywhere in the world.
- Unique Plasma emission detection
- Wide measurement range
- Lowest measurement range offers 10ppb resolution
Technology Used:
- Plasma Emission Detector - Servomex's unique non-depleting plasma emission cell offers an accurate, selective, and reliable measurement.
Features:
- Wide measurement range - 0-1ppm, 0-10ppm, 0-100ppm (higher on request)
- Ethernet remote control
- On lowest range - 10 ppb resolution / 2 ppb noise
- Low sample flow
- No moving parts, all solid state
- Maintenance free
Typical Applications:
- Air separation plants
- Argon purification plants
- Cryogenic truck loading station
- Speciality gas laboratories
- Process control
- Steel industry
- Chemical plants
- Gas management systems
- Welding gas control
- Helium liquification plants
SERVOPRO Plasma Data Sheet
|
|
|
|
SERVOPRO 4100 Gas Purity Analyser
The 4100 is designed to meet the product purity and plant control monitoring needs of industrial gas producers and users.
- Easy to set up and operate
- Low maintenance
- Extremely stable and reliable sensors
- Can measure up to four gases simultaneously
- External analogue input facilities
- RS232 serial data output
- Auto calibration as standard
Features:
- Simultaneously measures up to 4 gas streams
- Paramagnetic sensor with temperature control and pressure
- Compensation for ultimate performance
- Independent autocalibration of all measurements up to 8 isolated analogue outputs and up to 12 relays with follow or freeze option
- Alarm, fault and calibration history logs
- Bench top, panel or 19" rack mount
Typical Applications:
- Product purity on air separation plant
- Process control on air separation plant
- Inlet scrubber protection in air separation
- Bottling/filling plant applications
SERVOPRO 4100 Data Sheet
|
|
|
|
SERVOPRO 4200/4210 Industrial Multi-Component Gas Analyser
The 4200 is designed to monitor flammable gas samples including hydrogen/carbon monoxide, 'HYCO' or 'Syngas' mixtures for trace level contaminants and percent level components.
- Easy to set up and operate
- Low maintenance
- Extremely stable and reliable sensors
- Can measure up to four gases simultaneously
- External analogue input facilities
- RS232 / RS485 serial data output
- Modbus TM communications
- Autocalibration as standard
Technology used:
- Oxygen for purity control Servomex unique paramagnetic cell, which offers a fast, linear, accurate, highly stable and selective response in a non-depleting rugged package.
Carbon monoxide, carbon dioxide, nitrous oxide, methane at trace levels Single beam gas filter correlation photometric technology, which gives a highly stable, sensitive and selective measurement.
Features:
- Simultaneously measures up to 4 gas streams
- Paramagnetic sensor with temperature control and pressure compensation for ultimate performance
- Independent autocalibration of all measurements up to 8 isolated analogue outputs and up to 12 relays with follow or freeze option
- Alarm, fault and calibration history logs
- Bench top, panel or 19" rack mount
Typical applications:
- Product quality in hydrogen plant
- Process control on hydrogen or HYCO plant
- Bottling/filling plant for flammable gases
SERVORPO 4200/4210 Data Sheet
|
|
|
|
SERVOPRO 4900 Continuous Emissions Analyser
The 4900 is specifically designed for the Continuous Emissions Monitoring, where legislation requires the measurement of several gas components in flue gas.
- Low cost of ownership
- Multiple gas capability for pollutants, greenhouse gases and reference O2 (O2, CO, CO2, NO, SO2, CH4, N2O)
- Low maintenance
- Easy integration with other systems
- MCERTS / TÜV approved measurements
Technology Used:
- Oxygen Servomex's unique paramagnetic cell, which offers a fast, linear, accurate, highly stable and selective response in a non-depleting rugged package.
- Carbon monoxide, nitrous oxide, nitric oxide, sulphur dioxide, methane Single beam gas filter correlation photometric technology, which gives a highly stable, sensitive and selective measurement.
- Carbon monoxide, carbon dioxide at percent levels Single beam single wavelength photometric technology, which gives a stable, selective and cost effective measurement.
Features:
- Multiple gas measurements
- Minimum cabinet space
- Analogue and serial outputs
- External analogue inputs
- Automatic calibration
- Storage of fault and calibration data
Typical Applications:
- Utility Boilers
- Clinical waste incinerators
- Chemical incinerators
- Crematoria
- Mobile labs
- Research into greenhouse gases
SERVOPRO 4900 Data Sheet
|
|
|
|
SERVOFLEX Micro I.S
5100IS Intrisically Safe Portable Gas Analyser
The 5100 Intrinsically Safe Portable Gas Analyser is a single component, zone 0 and zone 1 hazardous area gas analyser.
- This unique analyser is certified to zone 0 without the need for purge.
- Suitable for measuring % levels of Oxygen and Carbon Dioxide.
- All sensors use non-depleting technologies, maximizing availability and reducing maintenance and operating costs.
Technology used:
- Oxygen a choice of two Servomex paramagnetic transducers (standard or high accuracy) both offering fast selective measurement of oxygen without the disadvantages of electrochemical or zirconia cells.
- Carbon Dioxide Single beam, single wavelength infrared technology using Servomex patented long life source gives a highly stable, selective and low maintenance measurement.
Features:
- Paramagnetic and Infrared sensors give reliable, accurate results with low maintenance and running costs.
- Suitable for use with flammable and toxic samples
- ATEX Certified as: Ex II 1G Ex ia IIC T4
- IEC Ex Certified as: Ex ia IIC T4
- Rugged, robust IP54 Construction
- Digital interface developed with customers to ensure desirable functions and ease of use.
- Fitted with a carrying strap for ease of use
- Up to 200 measurements can be stored in the analyser memory
- White backlit LCD Display
- User configurable, audible, concentration alarms
- Powered by advanced lithium ion rechargeable batteries
- Optional internal sample pump available
- Optional sample probe available
Typical applications:
- Hazardous area combustion optimization
- Natural gas processing
- Refineries catalytic cracker regeneration
- Hyco applications
- Cracker decoke cycle on petrochemical plant
- Process monitoring
- Inerting applications
SERVOFLEX Micro I.S. Data Sheet
|
|
|
|
SERVOFLEX MiniHD
5200HD Heady Duty Portable Gas Analyser
The 5200 HD portable gas analyser is a rugged, heavy duty analyser designed to accurately measure the composition of common gas mixtures, while in field locations or light industrial applications.
- Suitable for accurately measuring levels of oxygen or carbon dioxide
- All sensors use non-depleting technologies, ensuring the unit is always ready for use
- Robust IP65 construction that meets the demanding needs of field location analysis
- A range of sampling options to meet individual user requirements
- Long life Li-ion rechargeable batteries for maximum ease of use
- ORSAT validated to meet USFDA performance requirements for verifying medical oxygen USP and nitrogen NF
Technology Used:
- Oxygen a choice of two Servomex paramagnetic transducers (standard or high accuracy), both offering fast, selective measurement of oxygen without the disadvantages of electrochemical or zirconia cells.
- Carbon dioxide Single beam, single wavelength infrared technology using Servomex's patented long life source gives a highly stable, selective and low maintenance measurement.
Features:
- Paramagnetic and infrared sensors give reliable, credible results with low maintenance and running costs
- Small footprint, compact design and carrying strap ensure ease of use
- Digital interface developed with customers to ensure desirable functions
- User configurable concentration alarms and audible sounder
- Up to 200 measurement points can be stored in the analyser memory for later viewing
- White backlit LCD display
Typical Applications:
- Physiology studies
- Universities
- Combustion optimization
- Fermentation
- Medical gas verification
- Transformer entry
SERVOFLEX MiniHD Data Sheet
|
|
|
|
SERVOFLEX MiniMP
5200 Multi Purpose Portable Gas Analyser
The 5200 Multi Purpose portable benchtop analyser provides an ideal solution for determining the composition of common gas mixtures in laboratories and light industrial applications.
- Suitable for accurately measuring levels of oxygen and, from September 2005, carbon dioxide and carbon monoxide.
- All sensors use non-depleting technologies, maximising availability and reducing maintenance and running costs.
- Innovative construction gives a robust, single or dual measurement unit with space saving footprint.
- A range of sampling and power options to meet individual user requirements.
- Meets USFDA requirements for verification of medical oxygen USP and nitrogen NF.
Technology Used:
- Oxygen a choice of two Servomex paramagnetic transducers (standard or high accuracy), both offering fast, selective measurement of oxygen without the disadvantages of electrochemical or zirconia cells.
- From September '05, Methane, carbon dioxide or carbon monoxide Single beam, single wavelength infrared technology using Servomex's patented long life source gives a highly stable, selective and low maintenance measurement.
Features:
- Paramagnetic and infrared sensors give reliable, credible results with low maintenance and running costs
- Tower format saves space whilst offering dual measurement capability
- Digital interface developed with customers to ensure desirable functions and ease of use
- Reading available via backlit LCD display, RS 232 or optional mA output
- Print individual readings (printer optional) or log up to 200 measurements and transfer them to a PC
- User configurable concentration alarms and audible sounder
- Power options include mains (100-240V AC), vehicle socket (12/24V DC) or advanced Lithium ion rechargeable batteries (8-36 hours use depending on sensors selected and use of pump)
- Self monitoring software and Servomex support ensures user confidence
Typical Applications:
- Laboratories and research
- Air separation and gas bottling plants
- Medical gas storage facilities
- Physiology studies
- Respiration studies
- Douglas bag sampling
- Diving centres
- Double glazing manufacturers
- Fermentation
- Permeation studies
- Combustion analysis
SERVOFLEX MiniMP Data Sheet
|
|
|
|
K1550 Thermal Conductivity Gas Analyser
The K1550 is a highly stable thermal conductivity analyser including flexible package designed to give accurate measurements of hydrogen, helium, argon and carbon dioxide. More specialist measurements are available on request.
- Ease of use
- Stable and highly sensitive.
- Rapid response
- Low cost of long term ownership
Technology Used:
- Thermal conductivity - fast, non-depleting technology that offers a stable, reproducible measurement
Features:
- Gases measured include hydrogen, carbon dioxide and argon
- Hazardous-area sensor option
- 4 to 20mA isolated outputs
- Two user-configurable alarms
- Programmable alarms and analogue output
- Maintenance-free sensor
Typical Applications:
- Hydrogen in Chlorine
- Chlorine production
- Air separation plants
- Nitrogen in argon
- Iron and Steel
- Annealing furnaces
- Hydrogen production
K1550 Thermal Conductivity Gas Analyser Data Sheet
|
|
|
|
SERVOPRO 1440 General Purpose Gas Analyser
The 1440D provides a rack or panel mounted measurement of one or two of the following gases: oxygen, carbon dioxide, carbon monoxide and methane
- Excellent stability and performance
- Low maintenance
- No chemical cells to replace or renew
- Variants suitable for flammable / toxic sample gases
- Rack mounting or bench top
- Concentration and low flow alarms
Features:
- Measures one or two gases from either: oxygen,carbon dioxide, - carbon monoxide or methane.
- Concentration and low flow alarms
- Voltage and current outputs
- Bright LED display
Typical Applications:
- Landfill gas
- Fermentation processes
- Physiology testing
SERVOPRO 1440 Data Sheet
|
|